Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-15010 Rest Service Availability Failure

ALM-15010 Rest Service Availability Failure

Alarm Description

This alarm is reported when the heartbeat detection of the Rest service fails.

Attribute

Alarm ID

Alarm Severity

Alarm Type

15010

Major

Integrity violation

Alarm Parameters

Parameter

Description

Node

Specifies the node for which the alarm is reported.

CloudService

Specifies the service for which the alarm is generated.

Service

Specifies the service for which the alarm is generated.

MicroService

Specifies the microservice for which the alarm is generated.

solution

Specifies the method for handling the alarm

Impact on the System

If the Rest interface is unavailable, queues cannot be created or alarms cannot be reported.

Possible Causes

1. The network connection between the Manager service and the Rest service is abnormal.

2. The REST service is not started properly.

3. The Rest service process is running abnormally.

Procedure

  • The Rest process is not properly started.

    Rest depends on GlobalZK. Check whether GlobalZK works properly based on the log information.

  • The process is in the suspended state.

    Check whether the disk of the node where the Rest service resides is full or whether the Rest service is running properly.

    No manual intervention is required. After the upgrade or restart succeeds, the alarm is automatically cleared.

Alarm Clearing

This alarm will be automatically cleared after the fault is rectified.