Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-15023 Service Is Not Registered in Zookeeper

ALM-15023 Service Is Not Registered in Zookeeper

Alarm Description

Most services in DMS obtain IP addresses of other services using GlobalZK. These services register with the directories specified by GlobalZK during process startup. The health check process ops-check periodically checks whether these directories /register/core, /register/manager, /register/mas-api/business, /register/mas-api/manager, and /register/lb exist. If the directories do not exist, the alarm is reported.

Attribute

Alarm ID

Alarm Severity

Alarm Type

15023

Major

Communications alarm

Alarm Parameters

Parameter

Description

type

Specifies the health check type of the service.

Impact on the System

If /register/core does not exist, the Rest service may not be started properly and the system cannot generate or consume messages.

If /register/manager does not exist, the Manager service may not be started properly and the system cannot manage topics.

If /register/lb does not exist, the system can process API requests.

Possible Causes

The services corresponding to the paths are not started properly.

Procedure

Check whether the services corresponding to the directories and the services on which services depend are properly started based on the log.

Alarm Clearing

This alarm will be automatically cleared after the fault is rectified.