Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-1101320 The NPU Usage Exceeds the Threshold

ALM-1101320 The NPU Usage Exceeds the Threshold

Description

FusionSphere OpenStack periodically (every 5 minutes by default) checks the NPU usage in a host group. This alarm is generated when the NPU usage reaches 85% in the hosts.

This alarm is cleared when the NPU usage in the hosts is reduced to 70%.

Attribute

Alarm ID

Alarm Severity

Auto Clear

1101320

Warning

Yes

Parameters

Parameter

Meaning

Fault Location Info

  • aggregate_id: specifies the ID of the host group where NPU is located.
  • npu_type: specifies the type of the NPU.

Additional Info

  • Service: specifies the service for which the alarm is generated.
  • MicroService: specifies the microservice for which the alarm is generated.
  • aggregate_name: specifies the name of the host group where NPU is located.
  • npu_total: specifies the total number of NPUs.
  • npu_used: specifies the number of used NPUs.
  • threshold: specifies the NPU threshold.

Impact on the System

VMs with NPU installed may fail to create due to insufficient resources of NPU resources.

Possible Causes

The NPU usage is too high in the host group.

Procedure

  1. Obtain the NPU card type and host group information based on the alarm information. You are advised to add NPU cards of the same type to the host group for capacity expansion.
  2. After the NPU usage drops below 70%, check whether this alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. If any of the preceding operations fails, contact technical support for assistance.