Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EVT-1110000 Failed to Scale Up

EVT-1110000 Failed to Scale Up

Event Description

When the expected number of instances is manually changed or the conditions specified in a scaling policy are met, the scaling action is triggered and the Auto Scaling (AS) service calls the ECS creation API to create an Elastic Cloud Server (ECS) and calls the ELB API to bind the created ECS to a load balancer. This event is generated when an exception occurs in the process.

Event Attribute

Event ID

Event Type

1110000

QoS

Event Parameters

Name

Meaning

Event Name

Indicates the event name.

Event Source

Indicates the device for which the event is generated.

Source System

Indicates the event source.

IP Address

Indicates the IP address of the ECS for which the event is generated.

Occurred At

Indicates the last time when the event was generated.

Additional Information

Indicates the additional information about the event.

Impact on the System

  • This event has no adverse impact on the AS service.
  • Exceptions (may) occur for the in-progress scaling actions in the AS group for which the event is generated.

Possible Causes

  • An ECS service exception occurs.
  • An ELB service exception occurs.
  • The VDC quota is insufficient.

Procedure

  1. Log in to ManageOne Maintenance Portal using a browser.

    • URL: https://Address for accessing the homepage of ManageOne Maintenance Portal:31943, for example, https://oc.type.com:31943
    • Default username: admin; default password: Huawei12#$

  2. On the menu bar in the upper part of the page, choose Alarms. The Event Logs page is displayed.
  3. In the event list, locate and click the target event name in the Name column. The Event Details and Proposed Processing dialog box is displayed.
  4. In the displayed Event Details and Proposed Processing dialog box, query the following event information:

    • Event ID
    • Event Source
    • IP address: IP address of the server for which the alarm is generated
    • Location information: groupId and subTaskId
    • Additional information: error code and description of the event

  5. Contact technical support for assistance.