Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-514 Failed to Delete Created Volume

ALM-514 Failed to Delete Created Volume

Description

This alarm is reported when an exception occurs during volume resource cleanup.

Attribute

Alarm ID

Alarm Severity

Alarm Type

514

Minor

Environmental alarm

Parameters

Parameter Name

Parameter Description

kind

Resource type.

namespace

Name of the project to which the resource belongs.

name

Resource name.

uid

Unique ID of the resource.

OriginalEventTime

Event generation time.

EventSource

Name of the component that reports an event.

EventMessage

Supplementary information about an event.

Impact on the System

The volume cannot be used, causing volume waste.

System Actions

None

Possible Causes

The volume bound to the application is created successfully but the binding fails. Besides, the generated volume fails to be deleted. This may be caused by the abnormal storage function.

Procedure

  1. Use a browser to log in to the FusionStage OM zone console.

    1. Log in to ManageOne Maintenance Portal.
      • Login address: https://Address for accessing the homepage of ManageOne Maintenance Portal:31943, for example, https://oc.type.com:31943.
      • The default username is admin, and the default password is Huawei12#$.
    2. On the O&M Maps page, click the FusionStage link under Quick Links to go to the FusionStage OM zone console.

  2. Choose Project Management > Resource > Storage to check whether the storage function of the PVC works unexpectedly.

    • Yes: Go to 3.
    • No: Go to 4.

  3. Contact storage personnel to rectify the fault and then check whether the alarm is cleared.

    • Yes: No further action is required.
    • No: Go to 4.

  4. Contact technical support for assistance.

Alarm Clearing

This alarm must be manually cleared after the fault is rectified.