ALM-514 Failed to Delete Created Volume
Description
This alarm is reported when an exception occurs during volume resource cleanup.
Attribute
Alarm ID |
Alarm Severity |
Alarm Type |
---|---|---|
514 |
Minor |
Environmental alarm |
Parameters
Parameter Name |
Parameter Description |
---|---|
kind |
Resource type. |
namespace |
Name of the project to which the resource belongs. |
name |
Resource name. |
uid |
Unique ID of the resource. |
OriginalEventTime |
Event generation time. |
EventSource |
Name of the component that reports an event. |
EventMessage |
Supplementary information about an event. |
Impact on the System
The volume cannot be used, causing volume waste.
System Actions
None
Possible Causes
The volume bound to the application is created successfully but the binding fails. Besides, the generated volume fails to be deleted. This may be caused by the abnormal storage function.
Procedure
- Use a browser to log in to the FusionStage OM zone console.
- Log in to ManageOne Maintenance Portal.
- Login address: https://Address for accessing the homepage of ManageOne Maintenance Portal:31943, for example, https://oc.type.com:31943.
- The default username is admin, and the default password is Huawei12#$.
- On the O&M Maps page, click the FusionStage link under Quick Links to go to the FusionStage OM zone console.
- Log in to ManageOne Maintenance Portal.
- Choose to check whether the storage function of the PVC works unexpectedly.
- Contact storage personnel to rectify the fault and then check whether the alarm is cleared.
- Yes: No further action is required.
- No: Go to 4.
- Contact technical support for assistance.
Alarm Clearing
This alarm must be manually cleared after the fault is rectified.
Related Information
None