No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

HUAWEI CLOUD Stack 6.5.0 Alarm and Event Reference 04

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-70109 Residual Audit Alarm Related to VM BDM

ALM-70109 Residual Audit Alarm Related to VM BDM

Description

This alarm is generated when the drive letter allocation to a volume times out.

Attribute

Alarm ID

Alarm Severity

Auto Clear

70109

Major

Yes

Parameters

Name

Meaning

Fault Location Info

servicename: specifies the name of the service for which the alarm is generated.

Additional Info

detail_info: provides detailed information about the alarm.

Impact on the System

Residual VM BDM data exists in the system because the drive letter allocation to a volume times out when volumes are attached to the VM. This issue adversely affects system management over VMs.

Possible Causes

The drive letter allocation to a volume times out when the volume is being attached to the VM.

NOTE:

Obtain the audit issue that caused the alarm from the alarm details and handle the issue according to the following procedure.

Procedure

  1. Obtain the value of detail_info in Additional Info in the alarm details and the name of the corresponding audit report based on Table 3-2.

    Table 3-2 Mapping between detailed information and audit reports

    Details

    Audit Report

    audit_invalid_bdms

    invalid_bdms.csv

  2. Determine the deployment scenario of the current environment. Obtain the audit report.

  3. Determine the scenario where the current environment is deployed and obtain section "Analyzing Audit Results." Identify the handling method based on the audit report name and handle the audit items.

  4. Determine the scenario where the current environment is deployed and obtain section "Manual Audit." Start the system audit again.

    • Region Type I scenario:
    • Region Type II and Region Type III scenarios:

  5. Check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

  6. Contact technical support for assistance.

Related Information

None