Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-1005002 Abnormal communication between ADS and GaussDB 200

ALM-1005002 Abnormal communication between ADS and GaussDB 200

Description

This alarm is generated when the communication between the ADS and GaussDB 200 is abnormal.

Attribute

Alarm ID

Alarm Severity

Auto Clear

1005002

Major

Yes

Parameters

Name

Meaning

LibrA

Name and IP address of LibrA whose communication is abnormal

Impact on the System

Users fail to access the ADS console and fail to apply for ADS service instances.

Possible Causes

  • Network connection between the ADS and GaussDB 200 is abnormal.
  • Access between the ADS and LibrA is abnormal.

Procedure

  1. Use PuTTY to log in to EIS_PublicVM-Service1 and EIS_PublicVM-Service2 to manage VMs.

    Default account: ads; default password: Cloud12#$

  2. Run the following command to disable user logout upon session timeout:

    TMOUT=0

  3. Go to the opt/dbs/ads/log/run directory and view runTime.log.
  4. Locate the error log based on the location information in the alarm details on ManageOne Maintenance Portal.

    • If "Connection timed out" is displayed, the network connection is abnormal.
    • If "Login failed" is displayed, the password of the GaussDB 200 account is incorrect.
    • If other error messages are displayed, contact technical support for assistance.

Alarm Clearing

After the fault is rectified, the system will automatically clear the alarm.