Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0x10E01C0000 Failed To Add Backup Workflow Server Or Backup Proxy

0x10E01C0000 Failed To Add Backup Workflow Server Or Backup Proxy

Description

Failed to add backup proxy (IP: [IP_addr]).

Attribute

Alarm ID

Alarm Level

Manually Cleared

0x10E01C0000

Major

Yes

Parameters

Name

Meaning

IP_addr

IP address of backup Workflow Server Or Backup Proxy.

Impact on the System

N/A.

Possible Causes

  • The network connection between the backup workflow server (backup proxy) and backup manager (backup server) is interrupted.
  • The network performance is poor.

Procedure

  1. Possible cause 1: The network connection between the backup workflow server (backup proxy) and backup manager (backup server) is interrupted.

    1. Refer to Logging In to the eBackup Server to log in to eBackup-Manager or backup server.
    2. Run the su root command and enter the password of user root to switch to user root.

      The default password of user root is Cloud12#$.

    3. If the IP address is an IPv4 address, run the ping IP address of the backup workflow server or backup proxy command. If the IP address is an IPv6 address, run the ping6 IP address of the backup workflow server or backup proxy command. Check whether the IP addresses can be pinged.
      • If yes, 2.
      • If no, contact the equipment room administrator to recover the network connectivity and ensure that the network connection is normal.

  2. Possible cause 2: The network performance is poor.

    1. Check whether packet loss occurs based on the command output in 1.
      • If yes, contact the administrator to improve the network performance and ensure that the communication between the backup workflow server (backup proxy) and backup manager (backup server) is stable.
      • If no, 2.b.
    2. Log in to the backup manager or backup server GUI using a browser.

      Login address: https://IP address corresponding to the Workflow-Management-Float-IP field or IP address corresponding to the datamover_management_float_ip field:8088

      Default account: admin. Default password: Cloud12#$ for installation using HUAWEI CLOUD Stack Deploy, and PXU9@ctuNov17! for manual installation.

    3. Choose Monitor > Server. On the Server page that is displayed, check whether the backup server is in Accessible state.
      • If yes, 2.d.
      • If no, contact technical support engineers.
    4. Wait for about 3 minutes and check whether the alarm is cleared on the current alarm page.
      • If yes, no further action is required.
      • If no, contact technical support engineers.