Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-70135 The Ram Allocation Ratio Exceeds the Threshold

ALM-70135 The Ram Allocation Ratio Exceeds the Threshold

Description

After memory overcommitment is enabled on the host, the system periodically (5 minutes by default) checks the memory overcommitment rate. This alarm is generated when the memory overcommitment rate of the host exceeds the default alarm threshold (120% by default).

NOTE:

The memory overcommitment rate of the host is calculated as follows:

Host memory overcommitment rate = (Used memory – Memory reserved for VMs – Used huge page memory)/(Host physical memory – Reserved memory at the IaaS layer – Huge page memory)

Memory reserved for VMs = VM specifications x Memory reservation rate

The memory reservation rate can be adjusted on the FusionSphere OpenStack web client. The default value is 20%.

Passthrough VMs (GPU passthrough, SSD passthrough, SR-IOV passthrough, PF passthrough, FPGA passthrough, and NVDIMM passthrough) and huge page memory VMs do not support memory overcommitment. The memory reservation rate is 100%.

Attribute

Alarm ID

Alarm Severity

Auto Clear

70135

Major

Yes

Parameters

Name

Meaning

Fault Location Info

  • host_id: specifies the ID of the host for which the alarm is generated.

Additional Info

  • Service: specifies the service for which the alarm is generated.
  • MicroService: specifies the microservice for which the alarm is generated.
  • host_id: specifies the ID of the host for which the alarm is generated.
  • hostname: specifies the name of the host for which the alarm is generated.
  • overcommit_memory_total: specifies the total reusable memory of the host.
  • overcommit_memory_used: specifies the used reusable memory of the host.
  • ram_allocation_ratio: specifies the memory overcommitment ratio of the host.
  • threshold: specifies the memory overcommitment threshold of the host.

Impact on the System

The performance of VMs running on the host may deteriorate.

Possible Causes

A large number of VMs are running on the host.

Procedure

  1. Migrate some VMs on the host to another host to reduce the memory overcommitment rate of the host.

    For details, see "Migrating a VM" in the HUAWEI CLOUD Stack 6.5.0 O&M Guide.

  2. Wait for about 5 minutes and check whether the alarm is automatically cleared.

    • If yes, no further action is required.
    • If no, contact technical support for assistance.