Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-4104 Stack Running Is Abnormal

ALM-4104 Stack Running Is Abnormal

Description

This alarm is reported when health check detects that the stack is abnormal.

Attribute

Alarm ID

Alarm Severity

Alarm Type

4104

Major

Quality of service alarm

Parameters

Parameter Name

Parameter Description

stackName

Stack name.

StackGuid

Stack ID.

Impact on the System

Users cannot use the stack function.

System Actions

None

Possible Causes

  • The tenant's service application runs abnormally.
  • The tenant's service application has been deleted unintentionally.

Procedure

  1. Log in to FusionStage.

    1. Use a browser to log in to ManageOne Operation Portal (ManageOne Tenant Portal in B2B scenarios) as a VDC administrator or VDC operator.
      Login address:
      • Login address in a non-B2B scenario: https://Address for accessing ManageOne Operation Portal, for example, https://console.demo.com.
      • Login address in the B2B scenario: https://Address for accessing ManageOne Tenant Portal, for example, https://tenant.demo.com
    2. Select your region and then project from the drop-down list on the top menu bar.
    3. Choose Console > Application > FusionStage from the main menu.

  2. Click the stack for which this alarm is triggered. On the displayed Stack Detail page, choose Elements > Application to check whether the application has been deleted unintentionally.

    • If yes, go to 5.
    • If no, go to 3.

  3. Click an application name to check whether the application status is normal. Repeat this operation to check the statuses of all applications.

    • If yes, go to 6.
    • If no, go to 2.

  4. Restore the application to normal based on run logs of the application or other O&M information. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  5. Reinstall the stack and then check whether the alarm is cleared.

    1. On the Stack Detail page, choose More > Uninstall to uninstall the stack. After the stack is successfully uninstalled, the stack status switches to Initialized.

    2. On the Stack Detail page, choose More > Install to re-deploy the stack. After the stack is successfully installed, the stack returns to normal.

    • If yes, no further action is required.
    • If no, go to 6.

  6. Contact technical support for assistance.

Alarm Clearing

After the stack status is restored, you need to manually clear the alarm.