Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-6025 Data Store Usage Exceeds the Threshold

ALM-6025 Data Store Usage Exceeds the Threshold

Description

FusionSphere OpenStack periodically (default interval: 5 minutes) checks the data store usage. This alarm is generated when the data store usage is greater than or equal to the specified alarm threshold.

NOTE:
  • The default alarm threshold offset is 5%. The default alarm thresholds are as follows:
    • Critical: Data store usage > 95%
    • Major: 90% < Data store usage ≤ 95%
    • Minor: 85% < Data store usage ≤ 90%
    • Warning: 80% < Data store usage ≤ 85%
  • This alarm applies only to storage used by FusionSphere OpenStack, such as Huawei disk arrays and FusionStorage. To check whether the alarm is generated for storage used by FusionCompute or vCenter, see corresponding management software.

Attribute

Alarm ID

Alarm Severity

Auto Clear

6025

Critical/Major/Minor/Warning

Yes

Parameters

Name

Meaning

Fault Location Info

  • region: specifies the region where the backend storage for which the alarm is generated belongs.
  • backend: specifies the name of the backend storage for which the alarm is generated.

Additional Info

  • ThresholdLevel: specifies the data store usage threshold.
  • Service: specifies the service for which the alarm is generated.
  • MicroService: specifies the name of the microservice for which the alarm is generated.
  • Used Storage Capacity: specifies the capacity usage of the backend storage for which the alarm is generated.
  • region: specifies the region where the backend storage for which the alarm is generated belongs.
  • backend: specifies the name of the backend storage for which the alarm is generated.

Impact on the System

Storage performance deteriorates. If the storage space is insufficient, no storage resources are available in the system.

Possible Causes

Excessive storage resources are used, resulting in resource insufficiency.

Procedure

  1. Obtain the backend storage name based on the Fault Location Info and expand the capacity of the storage pool. If the storage pool uses SAN devices as the backend storage, expand the capacity by performing operations provided in the SAN device product documentation of the target version at https://support.huawei.com/enterprise/. If FusionStorage is used as the backend storage, see FusionStorage V100R006C30SPC500 Block Storage Service Capacity Adjustment Guide
  2. After the data store usage drops below 80%, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Contact technical support for assistance.