Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-MOBackupService_100002 No Backup Server Is Configured

ALM-MOBackupService_100002 No Backup Server Is Configured

Alarm Description

This alarm is generated when a delivered backup task fails to obtain backup server parameters.

Alarm Attribute

Alarm ID

Alarm Severity

Alarm Type

MOBackupService_100002

Major

Operation alarm

Alarm Parameters

Parameter

Description

Backup Server Type

The backup server type is SFTP.

Impact on System

The backup task fails to be executed.

Possible Causes

  • The backup server parameters are not configured.

Handling Procedure

  1. On ManageOne Maintenance Portal, choose System > Backup and Restoration from the main menu. In the navigation pane, choose Backup Policy to check whether a backup server is configured.

    • If yes, go to 5.
    • If no, check the configuration of the backup server by referring to Preparing the SFTP Server.

  2. Choose Backup Policy. If the transmission protocol of Basic Data is not the type provided in the alarm parameters, change the transmission protocol of Basic Data to the type provided in the alarm parameters.
  3. Select Basic Data and click Immediate backup.
  4. In the task list, wait until the backup task is complete and check whether the task is successfully executed.

    • If yes, no further action is required.
    • If no, go to 5.

  5. Collect the alarm handling information and contact technical support for assistance.

Alarm Clearance

This alarm will be automatically cleared after the fault is rectified.