No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

HUAWEI CLOUD Stack 6.5.0 Alarm and Event Reference 04

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-9204 Time Difference Between the OpenStack OM and the Upper-Layer Time Server Too Large

ALM-9204 Time Difference Between the OpenStack OM and the Upper-Layer Time Server Too Large

Description

The time management module monitors the running status of Network Time Protocol (NTP) service. This alarm is generated when the NTP service stops because the time difference between FusionSphere OpenStack OM and the upper-layer time server exceeds the threshold.

Attribute

Alarm ID

Alarm Severity

Auto Clear

9204

Major

Yes

Parameters

Name

Meaning

Fault Location Info

None

Additional Info

  • Local_Address: specifies the local IP address.
  • Peer_Address: specifies the peer IP address.

Impact on the System

Service OM cannot synchronize time with the upper-layer NTP server. As a result, the Service OM time is not accurate.

Possible Causes

If the time difference between Service OM and the upper-layer time server exceeds the threshold (60s), Service OM stops synchronizing time with the upper-layer NTP server.

Procedure

  1. Log in to the Service OM web client.

    For details, see Logging In to and Logging Out of Service OM.

  2. On the Service OM page, choose Services > Service OM > Centralized O&M > System > Time Management.
  3. On the Time Management page, click Synchronize Time Forcibly.

    System services will be restarted during forcibly time synchronization, which takes about 20 minutes.

  4. After about 20 minutes, log in to Service OM again, switch to the Time Management page, and check whether the forcible time synchronization is successful.

    • If yes, go to 5.
    • If no, go to 7.

  5. Check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

  6. Handle the time error by performing operations provided in "System Time Faults" in the HUAWEI CLOUD Stack 6.5.0 Troubleshooting Guide.
  7. Contact technical support for assistance.

Related Information