Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0x2010E01C0004 Sum Backup Proxy In System Reached The Upper Limit

0x2010E01C0004 Sum Backup Proxy In System Reached The Upper Limit

Description

The number of backup workflow servers or backup proxies reach the system upper limit.

Attribute

Alarm ID

Alarm Level

Manually Cleared

0x2010E01C0004

Major

Yes

Impact on the System

Registering a backup workflow server (backup proxy) onto the backup manager (backup server) will fail.

Possible Causes

The number of backup workflow servers or backup proxies reach the system upper limit.

Procedure

  1. Possible cause 1: The number of backup proxies reaches the system upper limit.

    1. Log in to the backup manager and backup server GUI in sequence using a browser.

      Login address: https://IP address corresponding to the Workflow-Management-Float-IP field or IP address corresponding to the datamover_management_float_ip field:8088

      Default account: admin. Default password: Cloud12#$ for installation using HUAWEI CLOUD Stack Deploy, and PXU9@ctuNov17! for manual installation.

    2. Choose Monitor > Server. On the Server page that is displayed and check whether the total number of backup proxies is more than 64.
      • If yes, 1.c.
      • If no, contact technical support engineers.
    3. Manually clear the alarm on the current alarm page.

Related Information