HUAWEI CLOUD Stack 6.5.0 Alarm and Event Reference 04

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-17 Failed to Pull Pod Software Package

ALM-17 Failed to Pull Pod Software Package

Description

This alarm is reported when an application instance fails to pull the software package.

Attribute

Alarm ID

Alarm Severity

Alarm Type

17

Major

Environmental alarm

Parameters

Parameter Name

Parameter Description

kind

Resource type.

namespace

Name of the project to which the resource belongs.

name

Resource name.

uid

Unique ID of the resource.

OriginalEventTime

Event generation time.

EventSource

Name of the component that reports an event.

EventMessage

Supplementary information about an event.

Impact on the System

The application running within the pod is abnormal, so that functions related to the application (pod) may be unavailable.

System Actions

The instance keeps pulling the software package.

Possible Causes

  • The configured software package path is incorrect.
  • The software package does not exist in the software repository.
  • The software repository is inaccessible.

Procedure

  1. Based on alarm parameters, check whether the software package keeps failing to be pulled due to incorrect package name. A package name should consist of a remote software package address and version. To obtain a software package address, click Repository > Software.

    • If yes, go to 2.
    • If no, go to 3.

  2. Correct the image name. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Check whether the remote software repository is accessible.

    • If yes, go to 6.
    • If no, go to 4.

  4. Restore the software repository. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  5. On the Marketplace page, choose Repository > Software to upload the correct software package. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

  6. Contact technical support for assistance.

Alarm Clearing

This alarm is automatically cleared after the fault is rectified.

Related Information

None