Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-126 Alarm of the Switchover to the Standby Syslog Server

ALM-126 Alarm of the Switchover to the Standby Syslog Server

Alarm Description

This alarm is generated when services are switched to the standby Syslog server because ManageOne fails to connect to the active Syslog server. This alarm is cleared after ManageOne successfully connects to the active Syslog server and services are switched back to the active Syslog server.

Alarm Attribute

Alarm ID

Alarm Severity

Alarm Type

126

Major

Environment alarm

Alarm Parameters

Name

Description

Master server IP address

IP address of the active Syslog server.

Master server port

Port number of the active Syslog server.

Standby server IP address

IP address of the standby Syslog server.

Standby server port

Port number of the standby Syslog server.

Impact on the System

Logs forwarded over the Syslog protocol are forwarded to the standby Syslog server instead of the active Syslog server.

System Actions

After ManageOne fails to connect to the active Syslog server, it connects to the standby Syslog server.

Possible Causes

  • The active Syslog server is not running.
  • ManageOne is disconnected from the active Syslog server.

Handling Procedure

  1. Check whether the active Syslog server is running properly.

    • If no, start the active Syslog server and go to 3.
    • If yes, go to 2.
      NOTE:

      Syslog servers are third-party servers. For details about how to check whether they are running or started, see the relevant description for third-party Syslog servers.

  2. Check whether the network connection between ManageOne and the active Syslog server is correct.

    1. Use PuTTY to log in to the MOC-ManageOne-Deploy01 node where the SMLogLic service is deployed as the ossadm user in SSH mode.
    2. Run the following command to check the network connection between ManageOne and the active Syslog server:

      ping IP address of the active Syslog server

      • If information similar to the following is displayed, the network connection is normal. Go to 3.
        64 bytes from IP address of the active Syslog server: icmp_seq=1 ttl=62 time=2.20 ms
      • If the information is not returned within 1 minute, the network is faulty. Rectify the fault and go to 3.
    3. Use PuTTY to log in to the MOC-ManageOne-Deploy02 node where the SMLogLic service is deployed as the ossadm user in SSH mode and perform 2.b.

  3. Wait for 30 seconds and check whether this alarm is cleared.

    • If yes, no further action is required.
    • If no, collect the information about alarm handling and contact Huawei technical support.

Related Information

None