No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

HUAWEI CLOUD Stack 6.5.0 Alarm and Event Reference 04

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0x201000F4000C VMware VMs Are Not Supported Currently

0x201000F4000C VMware VMs Are Not Supported Currently

Description

Currently, VMware VMs are not supported. The job for backing up VMware VMs will not be executed.

Attribute

Alarm ID

Alarm Level

Manually Cleared

0x201000F4000C

Warning

No

Impact on the System

The job for backing up VMware VMs will not be executed.

Possible Causes

The current license does not support backup of VMware VMs.

Procedure

  1. Possible cause 1: The current license does not support backup of VMware VMs.

    1. Apply for a license file that supports backup of VMware VMs by referring to License Functions and Features, Obtaining the ESN, and Applying for a License in the OceanStor BCManager 6.5.0 eBackup License Application Instructions.
    2. Log in to the backup server GUI using a browser.

      Login address: https://IP address corresponding to the datamover_management_float_ip field:8088

      Default account: admin. Default password: Cloud12#$ for installation using HUAWEI CLOUD Stack Deploy, and PXU9@ctuNov17! for manual installation.

    3. Choose Settings > License.
    4. Click Import. In the displayed dialog box, select the license file and click Open.
    5. Wait for about 3 minutes and check whether the alarm is cleared on the current alarm page.
      • If yes, no further action is required.
      • If no, contact technical support engineers.

Related Information

None