Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ETCD Residual Data

ETCD Residual Data

Symptom

The configuration file on the elb_lvs or elb_nginx node is inconsistent with that in the database.

Possible Causes

Redundant key data exists for ETCD services.

Procedure

  1. Use PuTTY to log in to the netcluster_elb_api_vm_1_01 node.

    The default username is elb and the default password is cnp200@HW.

  2. Run the following command to process residual data:

    curl {mgt_plane_ip}:8081/etcd_db_info_checked?operate=manual | python -m json.tool

    Replace {mgt_plane_ip} in the command with the management plane IP address of the elb_api node.

    The following information is displayed:

    {  
        "result": { 
          "absent": [ 
           { 
              "htype": "nginx-l7", 
              "listener_id": "19c6559e1a9644729ca5be987cd108be", 
              "operate": "updated" 
           } 
         ], 
         "nginxcluster": { 
             "absent": {}, 
             "redundant": {} 
              }, 
         "redundant": [ 
            { 
                "htype": "nginx-l7", 
                "listener_id": "9818360284e642b5a0bfa549e48b11d0", 
                "modifiedIndex": 14584, 
                "operate": "deleted" 
             }, 
             { 
                "htype": "lvs-l7", 
                "listener_id": "9818360284e642b5a0bfa549e48b11d0", 
                "modifiedIndex": 14583, 
                "operate": "deleted" 
             } 
           ] 
         }, 
         "status": 200 
    }

    redundant indicates residual data records. If the value of operate is deleted, a specified residual data record has been deleted.