display alarm history
Usage Guidelines
You can run the display alarm history command to view the alarms that are cleared or generated on the device.
Example
# Display historical alarms on the device.
<AC6605> display alarm history
A/B/C/D/E/F/G/H/I/J
A=Sequence, B=RootKindFlag(Independent|RootCause|nonRootCause)
C=Generating time, D=Clearing time
E=ID, F=Name, G=Level, H=State
I=Description information for locating(Para info, Reason info)
J=RootCause alarm sequence(Only for nonRootCause alarm)
1/Independent/2011-08-22 15:27:38/2011-08-22 15:42:51/0xff8c2028/hwFanInvalid/
Warning/End/OID 1.3.6.1.4.1.2011.5.25.219.2.6.5 Fan is invalid.(Index=16397, Ent
ityPhysicalIndex=16397, PhysicalName="FAN Card 0/1", EntityTrapFaultID=139264)
Item |
Description |
---|---|
A/B/C/D/E/F/G/H/I/J |
Alarm display format |
A=Sequence |
Sequence number |
B=RootKindFlag(Independent|RootCause|nonRootCause) |
Flag indicating a root-cause alarm or a non-root-cause alarm:
|
C=Generating time |
Time when an alarm is generated |
D=Clearing time |
Time when an alarm is cleared |
E=ID |
E=ID |
F=Name |
Alarm ID |
G=Level |
Alarm severity level You can run the alarm-name severity command to set this parameter. |
H=State |
Alarm status:
|
I=Description information for locating(Para info, Reason info) |
Alarm description including alarm parameters and causes for triggering alarms |
J=RootCause alarm sequence(Only for nonRootCause alarm) |
Sequence number of the root-cause alarm |