display alarm active
Usage Guidelines
You can run the display alarm active command to view active alarms on the device to locate faults.
Example
# Display active alarms on the device.
<AC6605> display alarm active A/B/C/D/E/F/G/H/I/J/K/L A=Sequence, B=RootKindFlag(Independent|RootCause|nonRootCause) C=Generating time, D=Clearing time E=ID, F=Name, G=MIDname, H=InfoAlias, I=Level, J=State K=Description information for locating(Para info, Reason info) L=RootCause alarm sequence(Only for nonRootCause alarm) 1/Independent/2011-08-22 15:27:38/-/0xff8c2028/hwFanInvalid/-/-/Warning/Start/OID 1.3.6.1.4.1.2011.5.25.219.2.6.5 Fan is invalid.(Index=16397, EntityPhysicalIndex =16397, PhysicalName="FAN Card 0/1", EntityTrapFaultID=139264)
Item |
Description |
---|---|
A/B/C/D/E/F/G/H/I/J/K/L |
Alarm display format. |
A=Sequence |
Sequence number. |
B=RootKindFlag(Independent|RootCause|nonRootCause) |
Flag indicating a root-cause alarm or a non-root-cause alarm:
|
C=Generating time |
Time when an alarm is generated. |
D=Clearing time |
Time when an alarm is cleared. |
E=ID |
Alarm ID. |
F=Name |
Alarm name. |
G=MIDname | Module ID name. |
H=InfoAlias | Alias name. |
I=Level |
Alarm severity level. To configure this parameter, run the alarm-name severity command. |
J=State |
Alarm status:
|
K=Description information for locating(Para info, Reason info) |
Alarm description including alarm parameters and causes for triggering alarms. |
L=RootCause alarm sequence(Only for nonRootCause alarm) |
Sequence number of the root-cause alarm (for non-root-cause alarms only). |