led off
Parameters
Parameter | Description | Value |
---|---|---|
time-range time-range-name | Specifies a time range. | The specified time range must exist. |
Usage Guidelines
Usage Scenario
Blinking indicators of indoor APs deployed in hospitals and hotels may affect people's nighttime rest. To prevent this, run the led off command to configured AP indicators to turn off or turn off during the specified time range.
If you need to locate AP faults by observing AP indicator status, run the undo led off command to allow the AP indicators to turn on.
Precautions
The configuration performed using the led blink-time command takes precedence over that performed using the led off command. That is, if AP indicators are configured to blink and to turn off or turn off during the specified time range, the configuration performed using the led off command takes effect after the RU indicators blink.