Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
duplex

duplex

Function

The duplex command configures the duplex mode on an Ethernet electrical interface in non-auto-negotiation mode.

The undo duplex command restores the default duplex mode on an Ethernet electrical interface in no-auto-negotiation mode.

By default, an Ethernet electrical interface works in full-duplex mode when auto-negotiation is disabled on the interface.

Format

duplex { full | half }

undo duplex

Parameters

Parameter

Description

Value

full

Configures the Ethernet interface to work in full-duplex mode when auto-negotiation is disabled on the interface.

-

half

Configures the Ethernet interface to work in half-duplex mode when auto-negotiation is disabled on the interface.

-

Views

GE interface view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

The duplex mode of an interface needs to be set in the following scenarios:
  • To enable an interface to send and receive packets at the same time, set the full-duplex mode on the interface.
  • To disable an interface from sending and receiving packets at the same time, set the half-duplex mode on the interface.

Prerequisites

The interface works in non-auto negotiation mode.

Precautions

  • A GE electrical interface that works at 1000 Mbit/s supports only the full-duplex mode. A GE electrical interface and its peer interface do not need to negotiate the duplex mode.

The interfaces on both ends of a link must have the same duplex mode.

Example

# Configure Ethernet electrical interface GE0/0/1 to work in half-duplex mode when non-auto negotiation is disabled on the interface.
<Huawei> system-view
[Huawei] interface gigabitethernet 0/0/1
[Huawei-GigabitEthernet0/0/1] undo negotiation auto
[Huawei-GigabitEthernet0/0/1] duplex half