Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
stp tc-protection threshold

stp tc-protection threshold

Function

The stp tc-protection threshold command sets the number of times that a device handles received TC BPDUs and updates forwarding entries within a unit time.

The undo stp tc-protection threshold command restores the default setting.

By default, after a device receives TC BPDUs, the default number of times that the device handles the TC BPDUs and updates forwarding entries is 1 within a unit time.

Format

stp tc-protection threshold threshold

undo stp tc-protection threshold

Parameters

Parameter Description Value
threshold Indicates the number of times that a device handles the TC BPDUs and updates forwarding entries per unit of time. The value is an integer ranging from 1 to 255.

Views

System view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

On a Layer 2 network where MSTP is run, a switching device that receives TC BPDUs will delete the corresponding MAC entries and ARP entries. Frequent deletion operations will greatly affect the CPU, leading to a high CPU usage.

After the stp tc-protection command is run to enable the TC BPDU attack defense function, the number of times that TC BPDUs are processed by the switching device within a unit time is configurable (the default unit time is 2s, and the default number of times is 1). If the number of TC BPDUs that the switching device receives within a unit time exceeds the specified threshold, the switching device handles TC BPDUs only for the specified number of times. Additional TC BPDUs are processed by the switching device as a whole for once after the timer (that is, the specified time period) expires. In this manner, the switching device is prevented from frequently deleting its MAC entries and ARP entries so that the CPU is protected against overburden.

The value of the unit time is consistent with the Hello time and can be set using the stp timer hello command.

Prerequisites

Before running the stp tc-protection threshold command, ensure that the stp tc-protection command is run to enable the TC BPDU attack defense function.

Example

# Set the threshold update forwarding entries to 5.
<Huawei> system-view
[Huawei] stp tc-protection threshold 5
Translation