Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
sample-time

sample-time

Function

The sample-time command sets the sampling interval for an RU.

The undo sample-time command restores the default sampling interval of an RU.

The default sampling interval of an RU is 30s.

Format

sample-time sample-time

undo sample-time

Parameters

Parameter

Description

Value

sample-time

Specifies the sampling interval.

The value is an integer that ranges from 2 to 300, in seconds.

Views

AP system profile view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

An RU collects statistics on data including AP-based, radio-based, and STA-based data that can be viewed using the display command at a specified interval.

Example

# Set the sampling interval to 50s.

<Huawei> system-view
[Huawei] wlan 
[Huawei-wlan-view] ap-system-profile name ap-system1
[Huawei-wlan-ap-system-prof-ap-system1] sample-time 50