Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
detect max-time

detect max-time

Function

The detect max-time command sets the maximum duration in which the SA module detects sessions.

The undo detect max-time command restores the maximum duration to the default value.

Format

detect max-time max-time

undo detect max-time

Parameters

Parameter Description Value
max-time Specifies the maximum session detection duration. The value is an integer ranging from 0 to 60, in minutes. The default value is 1.

Views

SA view

Default Level

2: Configuration level

Usage Guidelines

None

Example

# Set the maximum duration in which the SA module detects sessions to 5 minutes.

<Huawei> system-view
[Huawei] sa
[Huawei-sa] detect max-time 5