Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
suppression alarm-name

suppression alarm-name

Function

The suppression alarm-name command sets a period after which a generated alarm is reported. After the period is set, the alarm management module does not send the received alarm to the NMS until the period expires. If the period is set to 0s, the alarm management module sends the alarm to the NMS without any delay.

The undo suppression alarm-name command restores the period of delay in reporting alarms.

The system has defined a default period of delay in reporting alarms.

Format

suppression alarm-name alarm-name { cause-period cause-seconds | clear-period clear-seconds }

undo suppression alarm-name alarm-name { cause-period | clear-period }

Parameters

Parameter Description Value
alarm-name Specifies the name of an alarm for which the delay period is set. The value is a string of 1 to 64 case-insensitive characters, spaces not supported.
cause-period cause-seconds Specifies the period after which a generated alarm is reported. The value is an integer ranging from 0 to 600, in seconds.
clear-period clear-seconds Specifies the period after which a generated recovery alarm is reported. The value is an integer ranging from 0 to 600, in seconds.

Views

Alarm view

Default Level

2: Configuration level

Usage Guidelines

In the event that a certain alarm is repeatedly generated, you can enable delayed alarm reporting and set a period after which the alarm is reported to prevent the alarm from being reported during this period.

Before running the suppression alarm-name command, be sure that delayed alarm reporting has been enabled.

After the period is set for a certain alarm:

  • If no recovery alarm is generated during the period, the alarm is not reported to the NMS until the period expires.
  • If a recovery alarm is generated during this period, the alarm and its recovery alarm are both deleted from the alarm queue and will not be reported to the NMS.

The value of cause-period cause-seconds is irrelevant to the value of clear-period clear-seconds. Each alarm or its recovery alarm has its own default delay period.

If the delay period is too short, alarm reporting is not efficiently delayed. If the delay period is too long, alarm reporting is postponed and the time when the fault occurs cannot be correctly obtained. For most alarms, the default delay period is recommended. For common alarms, such as alarms about hardware and environment, delayed alarm reporting is not recommended.

If the delay period is changed when an alarm is being sent, the changed delay period takes effect on the next alarm to be sent.

Example

# Set the period of hwFileError alarm reporting delay to 5 seconds.

<Huawei> system-view
[Huawei] alarm
[Huawei-alarm] delay-suppression enable
[Huawei-alarm] suppression alarm-name hwFileError cause-period 5 