Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
clear alarm active

clear alarm active

Function

The clear alarm active command clears active alarms.

Format

clear alarm active { all | sequence-number sequence-number }

Parameters

Parameter Description Value
all Clears all active alarms. -
sequence-number sequence-number Specifies the sequence number of an active alarm.

The value is an integer ranging from 1 to 2147483647.

Views

Alarm view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

Before collecting statistics on alarms generated on the device again, run the clear alarm active to clear active alarms.

Precautions

After the clear alarm active command is used, all active alarms on the device are deleted and cannot be restored.

Example

# Clear all active alarms on the device.

<Huawei> system-view
[Huawei] alarm
[Huawei-alarm] clear alarm active all