sfn-roam roam-check high-threshold
Function
The sfn-roam roam-check high-threshold command sets the upper RSSI threshold for agile distributed SFN roaming.
The undo sfn-roam roam-check high-threshold command restores the default upper RSSI threshold for agile distributed SFN roaming.
By default, the upper RSSI threshold for agile distributed SFN roaming is -55 dBm.
Format
sfn-roam roam-check high-threshold high-threshold-value
undo sfn-roam roam-check high-threshold
Usage Guidelines
Usage Scenario
- When the HAP detects that the STA RSSI is lower than the lower threshold: The central AP makes a record if the SNR of the FAP is higher than that of the HAP.
- When the HAP detects that the STA RSSI is between the upper and lower thresholds: The central AP makes a record if the SNR of the FAP is 3 dB higher than that of the HAP.
- When the HAP detects that the STA RSSI is higher than the upper threshold: The central AP makes a record if the SNR of the FAP is 5 dB higher than that of the HAP.
Precautions
The lower RSSI threshold for agile distributed SFN roaming must be no higher than the upper threshold.