No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Fat AP and Cloud AP V200R010C00 Command Reference

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
poe power-off time-range

poe power-off time-range

Function

The poe power-off time-range command makes a configured PoE power-off time range effective on an interface.

The undo poe power-off time-range command cancels the configuration.

By default, a device is not configured with PoE power-off time range.

Only the AP8082DN, AP8182DN, AP4050DN-E, AP4050DN-HD, AP7050DN-E, AD9431DN-24X, AD9430DN-24, and AD9430DN-12 support this command.

Format

poe power-off time-range time-range-name

undo poe power-off time-range

Parameters

Parameter

Description

Value

time-range-name

Specifies a name for a PoE power-off time range.

The value is a string of 1 to 32 case-sensitive characters and must begin with a letter. In addition, the word all cannot be specified as a time range name.

Views

GE interface view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

The poe power-off time-range command makes a PoE power-off time range set in the system view effective on an interface. If the current time is within the specified time range, the PD connected to the interface cannot be powered on.

The undo poe power-off time-range command cancels the configuration. The time range does not take effect on the PD connected to the interface; however, the configuration of the time range is still saved.

The poe power-off time-range command is only applied to automatic power management mode.

Pre-configuration Tasks

Before running the poe power-off time-range command, you must ensure a PoE power-off time range has been configured through running the time-range command in the system view.

Example

# Configure a PoE power-off time range from 10:00 to 11:00 for PDs connected to GigabitEthernet0/0/1.
<Huawei> system-view
[Huawei] time-range PoE 10:00 to 11:00 daily
[Huawei] interface gigabitethernet 0/0/1
[Huawei-GigabitEthernet0/0/1] poe power-off time-range PoE