No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Fat AP and Cloud AP V200R010C00 Command Reference

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
alarm ip-used percentage

alarm ip-used percentage

Function

The alarm ip-used percentage command configures the percentage of the alarms indicating that the addresses in an address pool are used up, and the percentage of the clear alarms.

The undo alarm ip-used percentage command restores the default percentages of the alarms and clear alarms.

By default, the percentage of the alarms indicating that the addresses in an IP address pool are used up is 100%, and the percentage of the clear alarms is 50%.

Format

alarm ip-used percentage alarm-resume-percentage alarm-percentage

undo alarm ip-used percentage

Parameters

Parameter

Description

Value

alarm-resume-percentage Specifies the percentage of the clear alarms. The value is an integer that ranges from 1 to 100. The default value is 50.
NOTE:
The percentage of the clear alarms cannot exceed that of the alarms.
alarm-percentage Specifies the percentage of the alarms indicating that the addresses in an address pool are used up. The value is an integer that ranges from 1 to 100. The default value is 100.

Views

IP address pool view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

When the addresses in an IP address pool are used up, alarms are sent to notify the administrator.

Precautions

The percentage of the clear alarms cannot exceed that of the alarms.

Example

# Configure the percentage of the alarms indicating that the addresses in an address pool are used up, and the percentage of the clear alarms in the IP address pool view.

<Huawei> system-view
[Huawei] ip pool p1
[Huawei-ip-pool-p1] alarm ip-used percentage 80 90