No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Fat AP and Cloud AP V200R010C00 Command Reference

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
alarm-name severity

alarm-name severity

Function

The alarm-name severity command sets the severity for an alarm.

The undo alarm-name severity command restores the default setting.

By default, each alarm has a default severity.

Format

alarm-name alarm-name severity severity

undo alarm-name alarm-name severity

Parameters

Parameter Description Value
alarm-name Specifies the registered alarm name.

The value is of enumerated type and varies according to the registered device type.

NOTE:
To view registered alarm information, run the display alarm information command.
severity severity Specifies the alarm severity.
The value is of enumerated type. Alarms are classified into the following severities:
  • critical: indicates that a fault affecting services has occurred and it must be rectified immediately.
  • major: indicates that services are being affected and related measures need to be taken urgently.
  • minor: indicates that a fault occurs but does not affect services. To avoid more serious faults that affect services, related measures must be taken.
  • warning: indicates that a potential or impending service-affecting fault is detected before any significant effect has been felt. Take corrective actions to diagnose and rectify the fault.
  • indeterminate: indicates that the alarm severity cannot be determined.
  • cleared: indicates one or more previous alarm conditions have been cleared.

Views

Alarm view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

You can run the alarm-name severity command to change the alarm severity. You can configure filtering conditions to allow the NMS to receive only alarms of specified alarm severity.

Precautions

The default severity of each alarm is different. To view the default severity of an alarm, run the undo alarm-name severity and display alarm information commands in sequence.

Example

# Set the severity of the hwSysSlaveHDError alarm to warning.

<Huawei> system-view
[Huawei] alarm
[Huawei-alarm] alarm-name hwSysSlaveHDError severity warning
Translation
Download
Updated: 2019-11-21