No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Fit AP V200R010C00 Command Reference

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
parity

parity

Function

The parity command sets the parity bit of a user interface.

The undo parity command disables the parity check.

By default, no parity check is configured.

Format

parity { even | none | odd }

undo parity

Parameters

Parameter Description Value
even Specifies even parity check. -
none Specifies no parity check. -
odd Specifies odd parity check. -

Views

User interface view

Default Level

3: Management level

Usage Guidelines

This function takes effect for only serial interfaces.

Example

# Set the transmission parity bit on the console interface to odd parity.

<Huawei> system-view
[Huawei] user-interface console 0
[Huawei-ui-console0] parity odd
Translation
Download
Updated: 2019-07-18

Document ID: EDOC1100064353

Views: 90608

Downloads: 61

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next