Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
arp anti-attack log-trap-timer

arp anti-attack log-trap-timer

Function

The arp anti-attack log-trap-timer command sets the interval for sending ARP alarms.

The undo arp anti-attack log-trap-timer command restores the default setting.

The default interval for sending alarms is 0, indicating that the device does not send ARP alarms.

Format

arp anti-attack log-trap-timer time

undo arp anti-attack log-trap-timer

Parameters

Parameter Description Value
time Specifies the interval for sending ARP alarms. The value is an integer that ranges from 0 to 1200, in seconds.

Views

System view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

To allow the administrator to learn the ARP running status in real time, define potential attacks, and take measures, the device provides the alarm function for potential ARP attacks. This function records exceptions of ARP running in real time. To avoid excessive alarms when ARP attacks occur, reduce the alarm quantity by setting a proper interval for sending alarms.

Precautions

In the insecure environment, you are advised to extend the interval for sending ARP alarms. This prevents excessive ARP alarms. In the secure environment, you are advised to shorten the interval for sending ARP alarms. This facilitates fault rectification in real time.

After the interval is set, the device discards alarms generates in this interval; therefore, some faults cannot be rectified in real time.

Example

# Set the interval for sending ARP alarms to 20 seconds.

<Huawei> system-view
[Huawei] arp anti-attack log-trap-timer 20