Fit AP V200R010C00 Command Reference

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
info-center rate-limit monitor-period

info-center rate-limit monitor-period

Function

The info-center rate-limit monitor-period command sets the monitoring period for the information center to suppress the log processing rate.

The undo info-center rate-limit monitor-period command restores the default value.

By default, the monitoring period is 3 seconds.

Format

info-center rate-limit monitor-period value

undo info-center rate-limit monitor-period

Parameters

Parameter Description Value
value Specifies the monitoring period for the information center to suppress the log processing rate. The value is an integer ranging from 1 to 60, in seconds. The default value is 3.

Views

System view

Default Level

2: Configuration level

Usage Guidelines

The info-center rate-limit monitor-period command can be used to set a monitoring period for the information center to limit the log processing rate.
  • In the monitoring period specified by value, if the rate of sending a single log every second exceeds info-center rate-limit threshold, the information center will limit the log processing rate.
  • Then, in the monitoring period which is five times value, if the number of a single type of logs that are sent every second is smaller than info-center rate-limit threshold, the information center will no longer limit the log processing rate.

Example

# Set the monitoring period for the information center to suppress the log processing rate to 5 seconds.
<Huawei> system-view
[Huawei] info-center rate-limit monitor-period 5