Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
stopbits

stopbits

Function

The stopbits command sets the stop bit of a user interface.

The undo stopbits command restores the default stop bit of a user interface.

By default, the stop bit is 1.

Format

stopbits { 1.5 | 1 | 2 }

undo stopbits

Parameters

Parameter Description Value
1.5 Sets the stop bit to 1.5. -
1 Sets the stop bit to 1. -
2 Sets the stop bit to 2. -

Views

User interface view

Default Level

3: Management level

Usage Guidelines

If the stop bit is 1, the corresponding data bit is 7 or 8.

If the stop bit is 1.5, the corresponding data bit is 5.

If the stop bit is 2, the corresponding data bit is 6, 7, or 8.

This function takes effect for only serial interfaces.

NOTE:

On the console user interface, the stop bit 1.5 is not supported.

Example

# Set the stop bit of a user interface to 2.

<Huawei> system-view
[Huawei] user-interface console 0
[Huawei-ui-console0] stopbits 2