Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
virtual-cable-test

virtual-cable-test

Function

The virtual-cable-test command tests the cable connected to an Ethernet electrical interface and displays the test result.

Format

virtual-cable-test

Parameters

None

Views

GE interface view, MultiGE interface view

Default Level

3: Management level

Usage Guidelines

Usage Scenario

You can run the virtual-cable-test command to check whether the cable works properly. According to the command output, you can locate and rectify cable faults.
  • If the cable works properly, the total length of the cable is displayed.
  • If the cable cannot work properly, the distance between the interface and the fault point is displayed.

Precautions

  • Only the electrical interface or combo interface working as an electrical interface support the VCT function.
  • Running the virtual-cable-test command may affect services on the interface in a short period of time.
  • The VCT function is supported only when the local and peer ends work at 1000 Mbit/s in auto-negotiation mode.The VCT function is supported only by the R230D when its interfaces work at 100 Mbit/s in auto-negotiation mode.
  • When the cable works properly, the VCT function is not supported by all or some interfaces of the following APs. The cable length is 0 in the command output of interfaces.

  • If the cable cannot work properly, the distance between the interface and the failure point is displayed.
  • The test result is only for reference and may be inaccurate for cables of some vendors.
  • VCT detection cannot be performed on multiple interfaces of the device at the same time.
  • For wire sequence of cables, see Testing the Connection of Assembled Cables in the Hardware Installation and Maintenance Guide.

Example

# Test the cable connected to 0/0/1.

Table 5-9  Description of the virtual-cable-test command output

Item

Description

Pair A/B/C/D

Four pairs of circuits in a network cable.

Pair A length

Length of a network cable:
  • The length is the distance between the interface and the fault point if a fault occurs.
  • The length is the actual length of the cable when the cable works properly.

Pair A state

Network cable status:
  • Ok: indicates that the circuit pair is terminated normally.
  • Open: indicates that the circuit pair is not terminated.
  • Short: indicates that the circuit pair is short-circuited.
  • Crosstalk: indicates that the circuit pairs interfere with each other.
  • Unknown: indicates that the circuit pair has an unknown fault.