Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
display temperature

display temperature

Function

The display temperature command displays the device temperature.

Format

display temperature { all | slot slot-id }

Parameters

Parameter Description Value
all Displays the temperature of all boards. -
slot slot-id Displays the temperature of the specified board. The value is an integer and must be set according to the device configuration.

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

A high or low device temperature may damage the hardware. This command displays the current device temperature. When the device temperature exceeds the upper threshold or falls below the lower threshold, the device generates an alarm to alert you that the device temperature is abnormal.

NOTE:

The AP1010SN, AP2010DN, AP3010DN-AGN, AP5010DN-AGN, AP5010SN-GN, AP6010DN-AGN, AP6010SN-GN, AP6310SN-GN, AP430-E, R250D, AP1050DN-S, R450D, AP2030DN, AP3010DN-V2, AP3030DN, AP4030DN, AP4130DN, AP4050DN, AP4050DN-S, AP4051DN, AP4051DN-S, AP4151DN, AP2030DN-S, AP2051DN-L-S, WA375DD-CE, R230D, and R240D do not support query of the current device temperature.

Example

# Display the temperature of the device.

<Huawei> display temperature all
--------------------------------------------------------------------------------
 Slot  Card  Sensor No.  Sensor Name      Status  Upper  Lower  Temperature.(C) 
--------------------------------------------------------------------------------
 0     -     1           AP5030DN TEMP    NORMAL  102    -13    38              
Table 4-12  Description of the display temperature command output

Item

Description

Slot

Slot ID of the board.

Card

Subcard number.

Sensor No.

Number of the sensor on the board.

Sensor Name

Name of the sensor on the board.

Status

Board temperature:
  • NORMAL: The board temperature is within the allowed range.
  • ABNORMAL: The board temperature is out of the allowed range.

Upper

Upper threshold of the temperature.

Lower

Lower threshold of the temperature.

Temperature.(C)

Current temperature of the board, in the centigrade scale (C).

Translation
Download
Updated: 2019-07-18

Document ID: EDOC1100064353

Views: 92624

Downloads: 64

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next