Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
reset patch-configure

reset patch-configure

Function

The reset patch-configure command clears the patch settings.

Format

reset patch-configure next-startup

Parameters

Parameter Description Value
next-startup Clears the patch status and settings for the next startup. -

Views

User view

Default Level

3: Management level

Usage Guidelines

If you run the reset patch-configure next-startup command, the system clears the settings for the next startup patch and sets the patch status to idle.

Example

# Clear the patch status and settings for the next startup.

<Huawei> reset patch-configure next-startup
  The patch will be deleted. Continue? (y/n)[n]:y                               
Info: Succeeded in resetting the next-startup patch state.