No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

S12700 V200R013C00 Configuration Guide - Interface Management

This document describes the interface management configuration, including basic interface configuration, Ethernet interface configuration, and logical interface configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Interface Numbering Rules

Interface Numbering Rules

Management Interface Numbering Rules

The switch supports console and ETH management interfaces on an MPU.

The following table lists the management interface numbers.

Table 1-4  Management interface numbers

Interface

Number

Console interface

console 0

ETH interface

Ethernet 0/0/0

Physical Interface Numbering Rules

Physical interfaces are numbered in the following way:

A single switch uses slot ID/subcard ID/interface ID to identify physical interfaces.

A CSS switch uses chassis ID/slot ID/subcard ID/interface ID to identify physical interfaces.

  • Chassis ID: indicates the ID of a switch in the CSS. The value is 1 or 2.
  • Slot ID: indicates the number of the slot where a card is located.
  • Subcard ID: indicates the ID of a subcard.
  • Interface sequence number: indicates the sequence number of an interface on the card.

For example, if a card is inserted in slot 3 of a switch, the number of the fifth interfaces on the card that numbered from top to bottom and left to right is 3/0/4. If the switch is in a CSS and the CSS ID is 1, the interface is numbered 1/3/0/4.

Interface Numbering Diagram:
  • There are one row of interfaces on the interface card. The interfaces are numbered from left to right, starting with 0.

  • There are two rows of interfaces on the interface card. These interfaces are numbered from top to bottom and left to right, starting from 0.

100GE optical interfaces and some 40GE optical interfaces can be split into multiple interfaces. The converted interfaces are numbered using the following rules:

  • If a 40GE interface is numbered 40GE x/0/n, the four converted 10GE interfaces are numbered XGE x/1/(4n + z). For example, if a 40GE interface is numbered 40GE1/0/1, the four converted 10GE interfaces are numbered XGE1/1/4, XGE1/1/5, XGE1/1/6, and XGE1/1/7.

    If a 40GE interface is numbered 40GE x/1/n, the four converted 10GE interfaces are numbered XGE x/2/(4n + z + 8). For example, if a 40GE interface is numbered 40GE1/1/1, the four converted 10GE interfaces are numbered XGE1/2/12, XGE1/2/13, XGE1/2/14, and XGE1/2/15.

    • x: indicates the slot number of the card.
    • n: indicates the sequence number of the 40GE interface. The value starts from 0.
    • z: indicates the interface location. The value ranges from 0 to 3.
    NOTE:
    Split interfaces are numbered in the same sequence as the wires of a cable are numbered. For example, in a 1-to-4 cable, the wire numbered 1 corresponds to the interface with the lowest interface number, and the wire numbered 4 corresponds to the interface with the highest interface number.
  • After 100GE interfaces are split, the subcard number and interface sequence number of converted interfaces are fixed. Table 1-5 describes the numbering rules.

    Table 1-5  Numbering rule for interfaces converted from a 100GE interface

    100GE Interface Number

    Numbers of Converted 40GE Interfaces

    (EE Series Cards)

    Numbers of Ten Converted 10GE Interfaces

    (EE Series Cards)

    Numbers of Four Converted 10GE Interfaces

    (ET1D2C04HX2E, ET1D2C08HX2H, ET1D2C04HX2H and ET1D2C04HX2S Cards)

    Numbers of Four Converted 10GE Interfaces

    (ET1D2H02QX2E and ET1D2H02QX2S Cards)

    100GE x/0/0

    40GE x/1/0

    40GE x/1/1

    XGE x/2/0 to XGE x/2/9

    XGE x/1/0 to XGE x/1/3

    XGE x/2/0 to XGE x/2/3

    100GE x/0/1

    40GE x/1/2

    40GE x/1/3

    XGE x/2/10 to XGE x/2/19

    XGE x/1/4 to XGE x/1/7

    XGE x/2/4 to XGE x/2/7

    100GE x/0/2

    -

    -

    XGE x/1/8 to XGE x/1/11

    -

    100GE x/0/3

    -

    -

    XGE x/1/12 to XGE x/1/15

    -

Translation
Download
Updated: 2019-04-08

Document ID: EDOC1100065645

Views: 8778

Downloads: 23

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share