No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

S12700 V200R013C00 Configuration Guide - Reliability

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, NSR Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, MAC Swap Loopback Configuration, EFM Configuration, CFM Configuration, Y.1731 Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Association Between the BFD Session Status and the Interface Status

Association Between the BFD Session Status and the Interface Status

BFD for process interface status (PIS) associates the BFD session status with the interface status. This allows interfaces to be more sensitive to link faults and minimizes the impact of faults on indirectly connected links. When detecting a link fault, a BFD session immediately sends a Down message to the corresponding interface. The interface enters the BFD Down state and only processes BFD packets.

Application

Figure 2-7  Association between the BFD session status and the interface status

In Figure 2-7, transit devices are connected through a faulty link. Although they are directly connected at Layer 3, it will take SwitchA and SwitchB a long time to detect the fault because they are connected through multiple physical links. This will increase service interruption time. To prevent this, a BFD session is configured on SwitchA and SwitchB. The BFD session status is associated with the interface status. When a link fault is detected, a BFD session immediately sends a Down message to the corresponding interface and the interface enters the BFD Down state.

Translation
Download
Updated: 2019-04-08

Document ID: EDOC1100065654

Views: 28496

Downloads: 29

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share
Previous Next