This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, NSR Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, MAC Swap Loopback Configuration, EFM Configuration, CFM Configuration, Y.1731 Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Association Between a BFD Session and an Interface to Trigger the Associated Interface in Down State

Configuring Association Between a BFD Session and an Interface to Trigger the Associated Interface in Down State

Pre-configuration Tasks

Before configuring association between a BFD session and an interface, create a BFD session.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run oam-mgr

    The OAM management view is displayed.

  3. Run the following commands as required.

    • Run oam-bind ingress bfd-session bfd-session-id trigger if-down egress interface interface-type interface-number

      A BFD session is configured to report faults to an interface.

      By default, a BFD session is not enabled to report faults to an interface.

      When a BFD session detects a fault, the physical status of the interface bound to the BFD session becomes Down.

    • Run oam-bind ingress interface interface-type interface-number egress bfd-session bfd-session-id trigger if-down

      An interface is configured to report faults to a BFD session.

      By default, an interface is not enabled to report faults to a BFD session.

      When an interface becomes Down, the OAM management module sends a fault notification message to the BFD session bound to the interface. Then the fault notification message is sent to the remote device through the BFD session.

    • Run oam-bind bfd-session bfd-session-id trigger if-down interface interface-type interface-number

      The BFD session and the interface are configured to report faults to each other.

      By default, a BFD session and an interface are not enabled to report faults to each other.

      NOTE:

      If the oam-bind bfd-session bfd-session-id trigger if-down interface interface-type interface-number command is run, the oam-bind ingress bfd-session bfd-session-id trigger if-down egress interface interface-type interface-number and oam-bind ingress interface interface-type interface-number egress bfd-session bfd-session-id trigger if-down commands will be displayed in the configuration file.

      The physical interface associated with BFD cannot be the interface of the BFD link. Otherwise, a link deadlock occurs.