Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Monitoring the Running Status of Ethernet CFM

Monitoring the Running Status of Ethernet CFM

Context

To check the running status of Ethernet CFM during routine maintenance, run the following display commands in any view.

Procedure

  • Run the display oam global configuration command to check the global configuration of Ethernet OAM.
  • Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command to check information about a MEP.
  • Run the display cfm mip [ interface interface-type interface-number | level level ] command to check information about a MIP.
  • Run the display cfm remote-mep [ md md-name [ ma ma-name ] ] [ cfm-state { up | down | disable } ] command to check information about an RMEP.