Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
high-temperature threshold

high-temperature threshold

Function

The high-temperature threshold command sets the upper temperature alarm threshold for APs.

The undo high-temperature threshold command restores the default upper temperature alarm threshold for APs.

Table 11-109  Default upper temperature alarm threshold for APs

AP Model

Default Value (°C)

AP1010SN/R230D/R240D

40

AD9431DN-24X/AD9430DN-24

71

AP7110SN-GN

76

AP4050DN-HD

79

AP6510DN-AGN-US

81

AP8050DN/AP8050DN-S/AP8150DN/AP9330DN/AP7030DE

83

AP9131DN/AP9132DN

84

AP6010SN-GN/AP7060DN

85

AP8030DN/AP6050DN/AP6150DN/AP5050DN-S/WA375DD-CE

86

AP4030TN/AP5030DN/AP5130DN/AP5030DN-S

87

AP8130DN/AP7050DE/AP7052DN/AP7152DN/AP6052DN/AP4051TN/AP6510DN-AGN

88

AP7050DN-E/AP7110DN-AGN

89

AP4050DE-M/AP4050DE-M-S

90

AP8082DN/AP8182DN/AP8050TN-HD/AD9430DN-12

91

AP4050DN-E

92

AP6310SN-GN

94

AP7052DE/R251D/R251D-E

95

AP4050DN/AP1050DN-S/R450D

96

AP6610DN-AGN-US

100

R250D/R250D-E/AP6010DN-AGN

102

AP6610DN-AGN

104

NOTE:

The AP2010DN, AP3010DN-AGN, AP5010DN-AGN, AP5010SN-GN, AP4050DE-M, AP4050DE-M-S, AP3050DE, AP4050DE-B-S, AP2051DN-L-S, AP5510-W-GP, AP4030DN-E ,AP2030DN, AP2030DN-S, AP2050DN, AP2051DN, AP2050DN-S, AP2051DN-S, AP2050DN-E, AP2051DN-E, AP430-E, AP3010DN-V2, AP3030DN, AP4030DN, AP4051DN, AP4151DN, AP4050DN-S, AP4051DN-S and AP4130DN do not support this command.

Format

high-temperature threshold threshold

undo high-temperature threshold

Parameters

Parameter

Description

Value

threshold

Specifies the upper temperature alarm threshold.

The value is an integer that ranges from 20 to 110, in °C.

Views

AP system profile view

Default Level

2: Configuration level

Usage Guidelines

You can run this command to set the upper temperature alarm threshold for an AP. When an AP's temperature exceeds the upper threshold, the AP generates an alarm and a log, and notifies the AC of the high temperature.

Example

# Set the upper temperature alarm threshold for APs to 65°C.

<HUAWEI> system-view
[HUAWEI] wlan 
[HUAWEI-wlan-view] ap-system-profile name ap-system1
[HUAWEI-wlan-ap-system-prof-ap-system1] high-temperature threshold 65