S12700 V200R013C00 Command Reference

This document describes all the configuration commands of the device, including the command function, syntax, parameters, views, default level, usage guidelines, examples, and related commands.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
sta-load-balance dynamic probe-report interval

sta-load-balance dynamic probe-report interval

Function

The sta-load-balance dynamic probe-report interval command sets the interval for reporting Probe frames.

The undo sta-load-balance dynamic probe-report interval command restores the default interval for reporting Probe frames.

By default, Probe frames are reported at an interval of 120 seconds.

Format

sta-load-balance dynamic probe-report interval interval

undo sta-load-balance dynamic probe-report interval

Parameters

Parameter

Description

Value

interval

Specifies the interval for reporting Probe frames.

The value is an integer that ranges from 30 to 300, in seconds.

Views

RRM profile view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

After an AP receives information about neighboring APs of STAs, it reports the information to the AC for determining the target APs to which the STAs will roam. You can run the sta-load-balance dynamic probe-report interval command to set the interval at which the AP reports information about neighboring APs of the STAs.

Precautions

You are advised to retain the default value. If the device has high performance pressure, you can set a longer interval.

This command is valid only in sta-number mode.

Example

# Set the interval for reporting Probe frames to 125 seconds in RRM profile default.

<HUAWEI> system-view
[HUAWEI] wlan
[HUAWEI-wlan-view] rrm-profile name default
[HUAWEI-wlan-rrm-prof-default] sta-load-balance dynamic probe-report interval 125
Translation
Download
Updated: 2019-04-09