S12700 V200R013C00 Command Reference

This document describes all the configuration commands of the device, including the command function, syntax, parameters, views, default level, usage guidelines, examples, and related commands.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
low-temperature threshold

low-temperature threshold

Function

The low-temperature threshold command sets the lower temperature alarm threshold for APs.

The undo low-temperature threshold command restores the default lower temperature alarm threshold for APs.

Table 11-110  Default lower temperature alarm threshold for APs

AP Model

Default Value (°C)

R230D/R240D

0

AD9430DN-24/AD9431DN-24X/R250D/R250D-E/R251D/R251D-E

-3

AP1010SN

-10

AP5030DN-S/AP5130DN/AP5030DN/AP6150DN/AP4050DN-HD/AP4050DN-E/AP4030TN/AP4050DN/AP1050DN-S/AP7052DN/AP7152DN/AP7052DE/AP6052DN/AP4051TN/AD9430DN-12/AP6050DN/AP7050DE/AP7050DN-E/R450D/AP5050DN-S/AP6010DN-AGN/AP6010SN-GN/AP6310SN-GN/AP7110SN-GN/AP7110DN-AGN/AP9330DN/AP7060DN/AP4050DE-M/AP4050DE-M-S/WA375DD-CE

-13

AP7030DE

-23

AP8030DN/AP8050DN/AP8150DN/AP8050DN-S/AP8130DN/AP9131DN/AP9132DN/AP8082DN/AP8182DN/AP8050TN-HD/AP6510DN-AGN/AP6510DN-AGN-US/AP6610DN-AGN/AP6610DN-AGN-US

-43

NOTE:

The AP2010DN, AP3010DN-AGN, AP5010DN-AGN, AP5010SN-GN, AP4050DE-M, AP4050DE-M-S, AP3050DE, AP4050DE-B-S, AP2051DN-L-S, AP5510-W-GP, AP4030DN-E ,AP2030DN, AP2030DN-S, AP2050DN, AP2051DN, AP2050DN-S, AP2051DN-S, AP2050DN-E, AP2051DN-E, AP430-E, AP3010DN-V2, AP3030DN, AP4030DN, AP4051DN, AP4151DN, AP4050DN-S, AP4051DN-S and AP4130DN do not support this command.

Format

low-temperature threshold threshold

undo low-temperature threshold

Parameters

Parameter

Description

Value

threshold

Specifies the lower temperature alarm threshold.

The value is an integer that ranges from -70 to 10, in °C.

Views

AP system profile view

Default Level

2: Configuration level

Usage Guidelines

You can run this command to set the lower temperature alarm threshold for an AP. When an AP's temperature exceeds the lower threshold, the AP generates an alarm and a log, and notifies the AC of the low temperature.

Example

# Set the lower temperature alarm threshold for APs to 5°C.

<HUAWEI> system-view
[HUAWEI] wlan 
[HUAWEI-wlan-view] ap-system-profile name ap-system1
[HUAWEI-wlan-ap-system-prof-ap-system1] low-temperature threshold 5