S12700 V200R013C00 Command Reference

This document describes all the configuration commands of the device, including the command function, syntax, parameters, views, default level, usage guidelines, examples, and related commands.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
capwap echo

capwap echo

Function

The capwap echo command sets the CAPWAP heartbeat detection interval and the number of CAPWAP heartbeat detections.

The undo capwap echo command restores the default CAPWAP heartbeat detection interval and the number of CAPWAP heartbeat detections.

By default, the CAPWAP heartbeat detection interval is 25s and the number of CAPWAP heartbeat detections is 6.

By default, If dual-link backup is enabled, the CAPWAP heartbeat detection interval is 25s and the number of CAPWAP heartbeat detections is 3.

Format

capwap echo { interval interval-value | times times-value } *

undo capwap echo { interval | times }

Parameters

Parameter

Description

Value

interval interval-value

Specifies the CAPWAP heartbeat detection interval, the interval at which two detection packets are sent.

The value is an integer ranging from 20 to 300, in seconds.

times times-value

Specifies the number of CAPWAP heartbeat detections. If no response is received after the specified number of times, the link is considered disconnected.

The value is an integer ranging from 3 to 120.

Views

System view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

As defined by CAPWAP, an AP and an AC send handshake packets periodically to maintain the data channel and management channel. If the AP does not receive packets from the AC within the heartbeat detection interval, it considers that the link between them is disconnected. Then the AP resets and releases its IP address, and reestablishes a link. If the AC does not receive packets from the AP within the heartbeat detection interval, it disconnects the link between the AC and the AP and reports an error message to the AP.

Precautions

If dual-link backup is enabled, the CAPWAP heartbeat detection interval is 25s and the number of CAPWAP heartbeat detections is 3. When the Wireless Distribution System (WDS) is required in dual-link backup configuration, the WDS link may be unstable and users may not access the network. You need to run this command to set the interval for CAPWAP heartbeat detection to 25 seconds and the number of CAPWAP heartbeat detections to 6.

After the CAPWAP heartbeat detection interval and the number of CAPWAP heartbeat detections are configured, the interval and the number of times for sending Echo packets are configured.

Radio traffic statistics packets are sent and received together with Echo packets.

If you set the CAPWAP heartbeat detection interval and the number of CAPWAP heartbeat detections smaller than the default values, the CAPWAP link reliability is degraded. Exercise caution when you set the values. The default values are recommended.

Example

# Set the CAPWAP heartbeat detection interval to 30s and the number of CAPWAP heartbeat detections to 3.

<HUAWEI> system-view
[HUAWEI] capwap echo interval 30 times 3
Translation