No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

S12700 V200R013C00 Command Reference

This document describes all the configuration commands of the device, including the command function, syntax, parameters, views, default level, usage guidelines, examples, and related commands.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ISSU Configuration Commands

ISSU Configuration Commands

Command Support

ISSU is not supported on a switch in a CSS. Therefore, commands in this chapter cannot be configured on such a switch.

display issu backup state

Function

The display issu backup state command displays the status of data backup between the new master MPU and old master MPU.

Format

display issu backup state

Parameters

None

Views

User view

Default Level

3: Management level

Usage Guidelines

Usage Scenario

In ISSU start phase, you can use the display issu backup state command to view the status of data backup between the new master MPU and old master MPU to determine whether to switch the ISSU plane. ISSU plane switching is available only when the system is in real-time backup state.

ISSU enables the new master MPU and old master MPU to perform batch backup in three phases. Each service module backs up specific data in specific phases.
  1. Phase 1: Before the global configuration is restored, the system backs up the data required for restoring the global configuration.

  2. Phase 2: After the global configuration is restored and before the interface board configuration is restored, the system backs up the global data and data required for restoring the interface board configuration.

  3. Phase 3: After the interface board configuration is restored, the system backs up interface-related dynamic data.

Prerequisites

The issu check command has been used to enable the system to enter the ISSU check phase.

Example

# Display the status of data backup between the new master MPU and old master MPU.

<HUAWEI> display issu backup state
System backup status: real-time backup        
Table 2-70  Description of the display issu backup state command output

Item

Description

System backup status

The status of data backup between the new master MPU and old master MPU.
  • new plane init: indicates that the plane is initialized.

  • new plane ready: indicates that the plane is ready.

  • backup1: indicates batch backup in phase 1.

  • backup2: indicates batch backup in phase 2.

  • backup3: indicates batch backup in phase 3.

  • real-time backup: indicates real-time backup.

  • smooth: indicates data smoothing.

  • smooth-all-over: indicates that data smoothing ends.

  • unknown: indicates unknown.

Related Topics

display issu backup-result

Function

The display issu backup-result command displays the result of data backup in each phase of ISSU startup.

Format

display issu backup-result [ state { resource-prepare | backup-prepare | backup1 | backup2 | backup3 | smooth | smooth-all-over } ]

Parameters

Parameter Description Value
state

Indicates the data backup phase.

-

resource-prepare

Displays the resource preparation result.

-

backup-prepare

Displays the backup preparation result.

-

backup1

Displays the result of batch backup in phase 1.

-

backup2

Displays the result of batch backup in phase 2.

-

backup3

Displays the result of batch backup in phase 3.

-

smooth

Displays the result in data smoothing phase.

-

smooth-all-over

Displays the result in data smoothing end phase.

-

Views

User view

Default Level

3: Management level

Usage Guidelines

Usage Scenario

In ISSU start phase, you can use the display issu backup-result command to view the result of data backup in each phase.

ISSU enables the new master MPU and old master MPU to perform batch backup in three phases. Each service module backs up specific data in specific phases.
  1. Phase 1: Before the global configuration is restored, the system backs up the data required for restoring the global configuration.

  2. Phase 2: After the global configuration is restored and before the interface board configuration is restored, the system backs up the global data and data required for restoring the interface board configuration.

  3. Phase 3: After the interface board configuration is restored, the system backs up interface-related dynamic data. For example, the VRRP module must back up the data of the VRRP group, such as the VRRP backup status and the number of virtual IP addresses.

Prerequisites

After you use the issu check command to perform ISSU check, you can use the display issu backup-result command to view the result of data backup.

Example

# Display the result of data backup in each phase.

<HUAWEI> display issu backup-result
System backup-result:                                                           
-----------------------------------------------------------------------------   
State                            Result                                         
-----------------------------------------------------------------------------   
resource-prepare                 success                                        
backup-prepare                   success                                        
backup1                          success                                        
backup2                          success                                        
backup3                          success                                        
smooth                           -                                              
smooth-all-over                  -                                              
-----------------------------------------------------------------------------   
                                                                                
Interface board backup-result:                                                 
-----------------------------------------------------------------------------   
Slot                 State                                Result                
-----------------------------------------------------------------------------   
-----------------------------------------------------------------------------   

# Display the result of batch backup between the new master MPU and old master MPU in phase 2.

<HUAWEI> display issu backup-result state backup2
System backup-result:                                                           
-----------------------------------------------------------------------------   
State                            Result                                         
-----------------------------------------------------------------------------   
backup2                          success                                        
-----------------------------------------------------------------------------   
                                                                                
Interface board backup-result:                                                 
-----------------------------------------------------------------------------   
Slot                 State                                Result                
-----------------------------------------------------------------------------   
-----------------------------------------------------------------------------   
Table 2-71  Description of the display issu backup-result command output

Item

Description

System backup-result

Result of data backup between the new master MPU and old master MPU.

State

Phases for data backup between the new master MPU and old master MPU:
  • resource-prepare: indicates resource preparation.

  • backup-prepare: indicates backup preparation.

  • backup1: indicates batch backup in phase 1.

  • backup2: indicates batch backup in phase 2.

  • backup3: indicates batch backup in phase 3.

  • smooth: indicates data smoothing.

  • smooth-all-over: indicates that data smoothing ends.

Result

Result of data backup between the new master MPU and old master MPU:
  • success: indicates that data backup is successful.

  • failed: indicates that data backup fails.

  • -: indicates that the system has not entered the backup phase.

Interface board backup-result

Backup status of the interface board.

Slot

ID of the slot where the interface board is located.

State

Backup status of the interface board:
  • new plane init: indicates that the plane is initialized.

  • new plane ready: indicates that the plane is ready.

  • backup1: indicates batch backup in phase 1.

  • backup2: indicates batch backup in phase 2.

  • real-time backup: indicates real-time backup.

  • smooth: indicates data smoothing.

  • smooth-all-over: indicates that data smoothing ends.

  • unknown: indicates unknown.

Result

Result of data backup between interface boards:
  • success: indicates that data backup is successful.

  • failed: indicates that data backup fails.

  • -: indicates that the system has not entered the backup phase.

display issu check-result

Function

The display issu check-result command displays the result of ISSU check.

Format

display issu check-result

Parameters

None

Views

User view

Default Level

3: Management level

Usage Guidelines

Usage Scenario

After the ISSU check process is complete, you can run the display issu check-result command to check the ISSU modes supported by the system and maximum service interruption time.

The switch supports lossy ISSU. In lossy ISSU mode, the configuration of the old master MPU is synchronized to the new master MPU, and the configuration of the old process of a card is synchronized to the new process of the card. Dynamic data information, however, is not synchronized.

Prerequisites

After you use the issu check command to perform ISSU check, you can use the display issu check-result command to view the check result.

Example

# Display the result of ISSU check.

<HUAWEI> display issu check-result
System upgrade type      : lossy.
System maximum down time : 600 seconds.
Table 2-72  Description of the display issu check-result command output

Item

Description

System upgrade type

ISSU mode supported by the system:
  • Lossless ISSU

  • Lossy ISSU

System maximum down time

System maximum service interruption time, in seconds.

Related Topics

display issu module

Function

The display issu module command displays the service modules that support ISSU.

Format

display issu module

Parameters

None

Views

User view

Default Level

3: Management level

Usage Guidelines

Prerequisites

After the issu check command has been used to enable the system to enter the ISSU check phase the display issu module command can be used.
NOTE:
If the display issu module command is used before the ISSU check phase ends, incomplete information will be displayed.

Example

# Display the service modules that support ISSU.

<HUAWEI> display issu module
-----------------------------------------------------------
Slot                 ModuleId               ModuleName
-----------------------------------------------------------
 8                    0x41470000             AAA
 8                    0x40E90000             ND
 8                    0x40E00000             FIB6
 8                    0x41270000             RPR
 8                    0x416E0000             ARP
 8                    0x40A40000             CHDLC
 8                    0x400F0000             DHCPS
 8                    0x400D0000             DHCPR
 8                    0x40910000             FR
 8                    0x40CF0000             ATM
 8                    0x40010000             FIB
 8                    0x500000               IFNET
 8                    0x416C0000             BFD
 8                    0x417D0000             6OVER4
 8                    0x417E0000             TUNNEL6
 8                    0x40B60000             GRE
 8                    0x40B70000             TUNNEL
 8                    0x412F0000             L2VPN
 8                    0x41590000             TRUNK
 8                    0x411C0000             L2IF
 8                    0x40340000             VRRP
 8                    0x40800000             VGMP
 8                    0x41760000             DHCPSNP
 8                    0x419E0000             LAG
 8                    0x417A0000             RRPP
 8                    0x411E0000             MSTP
 8                    0x41920000             MINM
 8                    0x418F0000             802.1AG
 8                    0x418D0000             802.3AH
 8                    0x418E0000             OAM-MGR
 8                    0x41770000             QINQ
 8                    0x41820000             SNPG
 8                    0x41710000             MPLS OAM
 8                    0x40210000             MFIB
 8                    0x41B40000             MCTRUNK
 8                    0xFF880000             MID_ISSU_PDT
 8                    0x70010000             LSPM
 8                    0x705F0000             LDP
 8                    0x70230000             RSVP
 8                    0x70110000             ISIS
 8                    0x70120000             RM
 8                    0x70170000             OSPF
 8                    0x70180000             BGP
 8                    0x702B0000             TNLM
 8                    0x70320000             L3VPN V6
 8                    0x70040000             CSPF
 8                    0x70140000             RIP
 8                    0x70150000             RIPng
 8                    0x701D0000             OSPFv3
 8                    0x70240000             UDP6
 8                    0x70250000             RAW IP6
 8                    0x70260000             TCP6
 8                    0x70850000             KEY CHAIN
 8                    0x70190000             IGMP
 8                    0x701B0000             PIM
 8                    0x701E0000             MRM
 8                    0x701F0000             MRM6
 8                    0x70200000             MD
 8                    0x706E0000             MLD
 8                    0x706F0000             PIM6
 8                    0x702D0000             MSDP
-----------------------------------------------------------
Table 2-73  Description of the display issu module command output

Item

Description

Slot

Slot ID of the board.

ModuleId

ID of the module.

ModuleName

Name of the module.

Related Topics

display issu recover-configuration

Function

The display issu recover-configuration command displays the commands of which the configurations fail to be restored.

Format

display issu recover-configuration

Parameters

None

Views

User view

Default Level

3: Management level

Usage Guidelines

The display issu recover-configuration command displays the commands of which the configurations fail to be restored. You can manually restore the configurations of these commands.

You can run the display issu recover-configuration command for non-ISSU upgrade. During ISSU, this command can only be used on the new master MPU.

Example

# Display the commands of which the configurations fail to be restored.

<HUAWEI> display issu recover-configuration
-----------------------------------------------------------------
Slot                      ViewName                    CommandLine
Reason
-----------------------------------------------------------------------
9                         System-view                 display bgp peer
parse failure
9                         Interface Ethernet 1/0/0    display this
run failure
----------------------------------------------------------------------
Table 2-74  Description of the display issu recover-configuration command output

Item

Description

Slot

Board where the configuration needs to be restored.

ViewName

View in which the command is run.

CommandLine

Command of which the configuration fails to be restored.

Reason

Reason why the command configuration fails to be restored:
  • parse failure: indicates that the parsing of the command fails.

  • run failure: indicates that the execution of the command fails.

display issu state

Function

The display issu state command displays the current system ISSU state.

Format

display issu state

Parameters

None

Views

User view

Default Level

3: Management level

Usage Guidelines

You can use the display issu state command to view the current system ISSU state, including the ISSU check, ISSU start, ISSU switchover, and ISSU confirm states, to learn about the ISSU progress.

Example

# Display ISSU phase information.

<HUAWEI> display issu state
------------------------------------------------
Phase                 State
------------------------------------------------
1.ISSU check          finished
2.ISSU start          -
3.ISSU switchover     -
4.ISSU confirm        -
------------------------------------------------
The cancel ISSU command : issu abort.
Table 2-75  Description of the display issu state command output

Item

Description

Phase

ISSU phase information:
  • 1.ISSU check

  • 2.ISSU start

  • 3.ISSU switchover

  • 4.ISSU confirm

State

Backup status of the master MPU:
  • -: indicates that backup does not start.

  • finished: indicates that backup has finished.

  • processing: indicates that backup is being processed.

The cancel ISSU command

Command indicating version rollback.

display issu switch-result

Function

The display issu switch-result command displays the ISSU plane switchover to determine whether switchover check, switchover preparation, and data aging are successful.

Format

display issu switch-result { check | prepare | age }

Parameters

Parameter Description Value
check

Displays the result of switchover check.

-

prepare

Displays the result of switchover preparation, that is, the result of forwarding plane switchover.

-

age

Displays the result of data aging.

-

Views

User view

Default Level

3: Management level

Usage Guidelines

Usage Scenario

In ISSU switchover phase, you can use the display issu switch-result command to view the result of plane switchover in each phase.

ISSU plane switchover goes through four phases: switchover check, switchover preparation, data smoothing, and data aging. The switchover preparation phase is also called the forwarding plane switchover phase.

Prerequisites

After you use the issu check command to perform ISSU check, you can use the display issu switch-result command.

Example

# Display the result of switchover check on all interface boards.

<HUAWEI> display issu switch-result check
---------------------------------------------------------
Slot         Type                               Result
---------------------------------------------------------
13          new AMB                             succeeded 
Table 2-76  Description of the display issu switch-result command output

Item

Description

Slot

Slot ID of the board.

Type

Type of the master MPU or interface board process:
  • new RTP: indicates a new process on an interface board.

  • old RTP: indicates an old process on an interface board.

  • old master MPU

  • new master MPU

Result

Result of switchover check:
  • successed: indicates that switchover check is successful.

  • failed: indicates that switchover check fails.

  • unknown: indicates that the result of switchover check is unknown.

display issu timer rollback

Function

The display issu timer rollback command displays the value of the ISSU rollback timer and remaining time.

Format

display issu timer rollback

Parameters

None

Views

User view

Default Level

3: Management level

Usage Guidelines

Before ISSU, you can use the display issu timer rollback command to view the value of the ISSU rollback timer. During ISSU, you can use the display issu timer rollback command to view the value and remaining time of the ISSU rollback timer.

Example

# Display the ISSU rollback timer value before ISSU.

<HUAWEI> display issu timer rollback
Info: The ISSU rollback timer is not activated. The length of the rollback timer
 is 120 minutes. 

# Display the value and remaining time of the ISSU rollback timer during ISSU.

<HUAWEI> display issu timer rollback
Info: The length of the rollback timer is 120 minutes. There are 83 minutes left.
Table 2-77  Description of the display issu timer rollback command output

Item

Description

The ISSU rollback timer is not activated.

The ISSU rollback timer is not activated.

The length of the rollback timer is 120 minutes.

The ISSU rollback timer value is 120 minutes. To set the ISSU rollback timer value, run the issu timer rollback command.

There are 31 minutes left.

The remaining time of the ISSU rollback timer is 31 minutes.

Related Topics

issu abort

Function

The issu abort command aborts ISSU.

Format

issu abort

Parameters

None

Views

User view

Default Level

3: Management level

Usage Guidelines

During ISSU, you can run the issu abort command to abort ISSU. When the command is run in different situations, the command has different impacts on the system:
  • If you run the issu abort command before the standby MPU running the new version resets, the system exits ISSU.

  • If you run the issu abort command after the standby MPU running the new version resets and before the ISSU plane is successfully switched, the standby MPU rolls back to the old version, and the system exits ISSU.

  • If you run the issu abort command after the ISSU plane is successfully switched, the system cannot roll back and prompts that ISSU cannot be aborted.

Example

# Abort ISSU before restarting the standby MPU using the new version.

<HUAWEI> issu abort
Warning: The ISSU upgrade will be aborted, and the system will roll back to old version. Continue? [Y/N]: n
Info: This operation is canceled, and the system will continue ISSU process.

# Abort ISSU after the standby MPU restarts using the new version and before the ISSU plane is switched.

<HUAWEI> issu abort
Warning: The ISSU will be aborted, the system will be rolled back to the old version, and the new AMB will be rebooted. This operation will take 10 minutes. Continue? [Y/N]: y
Table 2-78  Description of the issu abort command output

Item

Description

Warning: The ISSU upgrade will be aborted, and the system will roll back to old version. Continue? [Y/N]:

  • If you enter y, the system aborts ISSU and rolls back to the old version.

  • If you enter n, the system aborts the execution of the issu abort command and continues ISSU.

Warning: The ISSU will be aborted, the system will be rolled back to the old version, and the new master MPU will be rebooted. This operation will take 10 minutes. Continue? [Y/N]:

  • If you enter y, the system aborts ISSU and rolls back to the old version, and the new master MPU restarts using the old version.

  • If you enter n, the system aborts the execution of the issu abort command and continues ISSU.

issu check

Function

The issu check command enables the system to enter the ISSU phase and perform ISSU check.

Format

issu check system-software system-file

Parameters

Parameter Description Value
system-software system-file

Specifies the name of the system software file.

The value is a string of 4 to 48 case-sensitive characters without spaces.

Views

User view

Default Level

3: Management level

Usage Guidelines

Usage Scenario

If you run the issu check command in real-time backup phase, the system enters the ISSU check phase.

In the ISSU check phase, the system performs resource check and compatibility check to determine whether the upgrade can be performed. ISSU resource check is performed to check whether the current system resources support ISSU. ISSU compatibility check is performed to determine the upgrade mode used on each card (common restart mode or fast restart mode).

Prerequisites

The system software to be upgraded has been uploaded to all MPUs.

Configuration Impact

The ISSU check affects the system in the following aspects:
  • Operational and configuration commands except ISSU commands and some query commands will be shielded. You can enter a question mark (?) to check which commands can be executed.

  • The standby MPU restarts using the new version and becomes the new master MPU.

  • The ISSU rollback timer is activated. You can adjust the ISSU rollback timer value during ISSU. If the timer expires before ISSU is complete, ISSU may fail and then the system will roll back to the old version.

NOTE:
Before the ISSU check phase ends, you can press Ctrl+C to abort ISSU. Then the system continues ISSU check until ISSU check finishes. You cannot continue ISSU but only run the issu abort command to exit ISSU.

Example

# Perform ISSU check.

<HUAWEI> issu check system-software S12700V200R013C00.cc
Warning: The value of the ISSU rollback timer is 120 minutes. The system will begin the ISSU upgrade. The current configuration will be saved to the new version's startup configuration file. Continue? [Y/N]: y.
Info: The system is comparing compatibility ID...
Info: The system is checking the hardware compatibility...
Error: Some boards do not support ISSU. The upgrade of the boards is configured to common reboot mode. The detailed information about the boards can be viewed by using the display command (display issu check-result).
Info: The slave board is rebooting in flash:/S12700V200R013C00.cc..........................................................................................................
Info: The new AMB is registered.
Info: The system is generating the configuration file.....
Info: The system supports lossy ISSU.
Info: Any of the following operations can be performed as required:
1. View detailed information about ISSU check result by using the display command (display issu check-result).
2. The ISSU rollback timer can be configured before ISSU start by using the command (issu timer rollback). The default value of the timer is 120 minutes.
3. To start ISSU, Run the command (issu start). Otherwise, the system will roll back to the old version after the ISSU timer time out.
4. To roll back the system to the old version immediately, run the command (issu abort).
Table 2-79  Description of the issu check command output

Item

Description

Warning: The value of the ISSU rollback timer is 120 minutes. The system will begin the ISSU upgrade. The current configuration will be saved to the new version's startup configuration file. Continue? [Y/N]

  • If you enter y, the system starts ISSU and performs ISSU check.

  • If you enter n, the system aborts the execution of the issu check command and then exit ISSU.

issu confirm

Function

The issu confirm command confirms ISSU after the ISSU plane is successfully switched so that the old master MPU restarts using the new version.

Format

issu confirm

Parameters

None

Views

User view

Default Level

3: Management level

Usage Guidelines

Usage Scenario

If you confirm that ISSU is successful and version rollback is not required, run the issu confirm command to enter the ISSU confirm phase. In this phase, the old master MPU restarts using the new version, and the system clears temporary data generated during ISSU and finishes ISSU.

Prerequisites

The issu switchover command has been used to switch the ISSU plane.

Configuration Impact

After the issu confirm command is executed, the new system software is specified as the software for the next startup. The ISSU is complete.

Example

# Check whether ISSU is successful and the system exits ISSU.

<HUAWEI> issu confirm
Info: The slave MPU running the target version is restarting. After the reboot c
ompleted, the system will automatically exit from the ISSU process.             
Related Topics

issu precheck

Function

The issu precheck command enables the system to perform in-service software upgrade (ISSU) precheck. This helps determine whether ISSU can be performed.

Format

issu precheck system-software system-file

Parameters

Parameter Description Value
system-software system-file

Specifies the name of the system software file.

The value is a string of 4 to 48 case-sensitive characters without spaces, in the format of [drive][file-name]. The default drive is flash:/.

Views

User view

Default Level

3: Management level

Usage Guidelines

Before an ISSU upgrade, run this command to perform an ISSU precheck and determine whether the current system resources (software version, number of VTY users, and memory space on the cards) and card type support ISSU. If the current software version does not support ISSU or there are more than one VTY user in the system, the system stops the precheck and the ISSU upgrade cannot be performed. If a card does not have sufficient memory space, this card does not respond to the ISSU instructions and must be upgraded by resetting it.

The ISSU precheck hardly affect system operation and can be performed at any time except in an ISSU process.

Different from issu check, the issu precheck command only checks whether the current system resources and card type support ISSU. The displayed upgrade type in the check resource may not be the final upgrade type used on the cards. The final upgrade type will be displayed in the check result after you run the issu check command.

Example

# Perform ISSU precheck to determine whether ISSU can be performed.

<HUAWEI> issu precheck system-software S12700V200R013C00.cc
System upgrade type      : lossy.                                               
System maximum down time : 600 seconds.                                         
Interface board compatibility:                                                  
----------------------------------------------------------------------------    
Slot                Type SupportStatus   MaxDownTime(s) Reason                  
----------------------------------------------------------------------------    
1                   LPU  fast-reboot                600 NULL                    
2                   LPU  fast-reboot                600 NULL                    
3                   LPU  fast-reboot                600 NULL                    
----------------------------------------------------------------------------    
Table 2-80  Description of the issu precheck command output

Item

Description

System Upgrade Type

ISSU mode supported by the system:
  • Lossless ISSU

  • Lossy ISSU

System Maximum Down Time

System maximum service interruption time, in seconds.

Interface board compatibility

Result of card compatibility check.

Slot

Slot ID of a card.

Type

Card type, which is usually Line Processing Unit (LPU).

SupportStatus

ISSU mode supported by a card:
  • common-reboot: common restart

  • fast-reboot: fast restart

MaxDownTime(s)

Maximum service interruption time of a card, in seconds.

Reason

Reason why a card does not support ISSU:
  • not enough memory: indicates that memory is insufficient.

  • null: indicates that the card supports ISSU.

Related Topics

issu start

Function

The issu start command starts ISSU.

Format

issu start

Parameters

None

Views

User view

Default Level

3: Management level

Usage Guidelines

Usage Scenario

During data backup, you can run the display issu backup state command to view the backup status. After data backup, you can run the display issu backup-result command to view the result of data backup.
NOTE:
After the system starts ISSU, you can press Ctrl+C to abort ISSU. Then the system aborts ISSU. You cannot continue to switch the ISSU plane but only run the issu abort command to exit ISSU.

Prerequisites

The issu check command has been used to enable the system to perform ISSU check.

Example

# Start lossless ISSU.

<HUAWEI> issu start
Info: The Lossy ISSU process will start. Continue? [Y/N]:y
Info: The system will start lossy ISSU upgrade.
Info: The system is copying the configuration file...
Info: The operation of copying the configuration file is complete.
Info: The system is preparing resources...
Info: The resource preparation is complete.
Info: The system is preparing for batch backup...
Info: The preparation for batch backup is complete.
Info: The system is busy with phase 1 batch backup...
Info: Phase 1 batch backup is complete.
Info: The system is busy with configuration recovery of the new AMB...
Warning: Some errors occurred in the configuration recovery of the new AMB phase. The top error level: Not Affect ISSU Upgrade. Detailed information can be obtained by using the command (display issu recover-configuration) in the new AMB.
Info: Configuration recovery of the new AMB is complete.
Info: The system is busy with phase 2 batch backup...
Info: Phase 2 batch backup is complete.
Info: Configuration of interface boards is recovering...
Info: Configuration recovery of interface boards is complete.
Info: The system is busy with phase 3 batch backup...
Info: Phase 3 batch backup is complete.
Info: The system is in real-time backup phase. Please check the backup status before performing the ISSU switchover (Command: display issu backup state; issu switchover).
Table 2-81  Description of the issu start command output

Item

Description

Info: The Lossy ISSU process will start. Continue? [Y/N]:

  • If you enter y, the system starts lossy ISSU.

  • If you enter n, the system aborts the execution of the issu start command and waits for the next operation:
    • To continue ISSU, run the issu start command according to the prompt before the ISSU rollback timer expires.

    • To abort ISSU, run the issu abort command.

    • If you do not run the issu start or issu abort command, the system rolls back and exits ISSU after the ISSU rollback timer expires.

issu switchover

Function

The issu switchover command configures the system to switch the ISSU plane.

Format

issu switchover [ force ]

Parameters

Parameter Description Value
force

Switches the ISSU plane forcibly. If this parameter is specified, the ISSU plane is forcibly switched even if data backup errors are detected during ISSU check. Otherwise, the system prompts you whether to continue the ISSU plane switchover.

-

Views

User view

Default Level

3: Management level

Usage Guidelines

Usage Scenario

You can run the issu switchover command to switch the ISSU plane. The switchover process includes switchover check, forwarding plane switchover (switchover preparation), data smoothing, and data aging. Before the ISSU plane switchover, if errors occur during data backup, you are prompted to perform the forcible switchover; if data backup is found incomplete, you can prompted to perform the command later.
NOTE:
  • The ISSU plane switchover will interrupt a Telnet connection for 30s. Wait for 30s and then press Enter to re-log in to the device for ISSU.

  • After you run the issu confirm command to confirm ISSU and restart the old master MPU using the new version, check the status of the master MPU and standby MPU again. Then you can find that the new master MPU is in Master state because the hardware switchover has completed.

Prerequisites

Before you use the issu switchover command to switch ISSU plane, the issu start command has been used to start ISSU and ISSU is in real-time backup state.

Example

# Enter the ISSU plane switchover phase.

<HUAWEI> issu switchover
Info: The system will check the ready mode of all modules first. Please wait... 
Info: The check for the switchover between forwarding planes starts...          
Info: The check for the switchover on slot 4 succeeded.                         
Info: The check for the switchover on slot 5 succeeded.                         
Info: The check for the switchover between forwarding planes is complete.       
Info: The switchover between the forwarding planes starts....                   
Info: The switchover on slot 4 succeeded.                                       
Info: The switchover on slot 5 succeeded.                                       
Warning: The connect of telnet will be down, please retry after 30 seconds.     

issu timer rollback

Function

The issu timer rollback command sets the ISSU rollback timer value.

Format

issu timer rollback time

Parameters

Parameter Description Value
time

Specifies the ISSU rollback timer value.

The value is an integer ranging from 60 to 2880, in minutes. The default value is 120 minutes.

Views

User view

Default Level

3: Management level

Usage Guidelines

After the system enters the ISSU check phase, the ISSU rollback timer is automatically activated. If the timer expires in different situations, the system uses different processing methods:
  • If the timer expires before the standby MPU restarts using the new version, the system considers that you abort ISSU and exits ISSU.

  • If the timer expires after the standby MPU restarts using the new version and before the ISSU plane is successfully switched, the system considers that you abort ISSU, the standby MPU rolls back to the old version, and then the system aborts ISSU.

  • If the timer expires after the ISSU plane is successfully switched, the system extends the upgrade time and considers that ISSU is successful by default.

Before the ISSU plane is switched, you can run the issu timer rollback command to reset the ISSU rollback timer value. In ISSU confirm phase, if ISSU is confirmed successful, the ISSU rollback timer is automatically disabled.

Example

# Set the ISSU rollback timer to 60 minutes.

<HUAWEI> issu timer rollback 60
Translation
Download