Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
TUNN_PS

TUNN_PS

TUNN_PS/5/BATCH_BKP_SUCCESS

Message

TUNN_PS/5/BATCH_BKP_SUCCESS:Tunnel PS finished batch backup successfully.

Description

The batch backup of the protection group ended.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

The batch backup of the protection group ended.

Procedure

  1. This log message indicates a normal situation, and no action is required.

TUNN_PS/4/CLEAR_SIGNAL_FAIL

Message

TUNN_PS/4/CLEAR_SIGNAL_FAIL:Can not clear the Signal-Fail.

Description

The current switching result is signaling switching, and thus signaling switching cannot be cleared.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

The signaling switching command is incorrect.

Procedure

  1. Run the display current-configuration command to check whether the configuration is correct.

TUNN_PS/2/DEL_PS_PTUNN_FAIL

Message

TUNN_PS/2/DEL_PS_PTUNN_FAIL:Failed to get the protection tunnel when delteing protection group! (Index=[ULONG])

Description

The protection tunnel cannot be found during the deletion of the protection group.

Parameters

Parameter Name Parameter Meaning
Index indicates the index of a protection tunnel.

Possible Causes

The backup LSP cannot be found.

Procedure

  1. Check whether the configuration of the protection group is correct. If incorrect, reconfigure the protection group.

TUNN_PS/2/DEL_PS_WTUNN_FAIL

Message

TUNN_PS/2/DEL_PS_WTUNN_FAIL:Failed to get the work tunnel when delteing protection group! (Index=[ULONG])

Description

The working tunnel cannot be found during the deletion of the protection group.

Parameters

Parameter Name Parameter Meaning
Index indicates the index of a working tunnel.

Possible Causes

During the deletion of the protection group, information about the working tunnel cannot be found according to the index of the working tunnel.

Procedure

  1. Check whether the configuration of the protection group is correct.
  2. Check whether the status of the protection tunnel is normal.
  3. Collect the error information prompted by the system.
  4. Collect log information and configuration information, and then contact technical support personnel.

TUNN_PS/2/INFO_CMD_DISP

Message

TUNN_PS/2/INFO_CMD_DISP:Cann't get the cr-lsp when executing the command of display!

Description

The CR-LSP cannot be found when the display command was processed.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

The interface information obtained according to the working tunnel ID was null, and information about the CR-LSP in the interface information was null.

Procedure

  1. Check whether the configuration of the protection group is correct.
  2. If the configuration is incorrect, reconfigure the protection group.

TUNN_PS/6/NOTIFY_DELETE_AUTOTUNNEL

Message

TUNN_PS/6/NOTIFY_DELETE_AUTOTUNNEL:Receive Delete Auto Frr Tunnel message! (ulIfIndex=[ULONG])

Description

Received the Delete Auto FRR Tunnel message.

Parameters

Parameter Name Parameter Meaning
ulIfIndex indicates the index of an interface.

Possible Causes

Received the Delete Auto FRR Tunnel message.

Procedure

  1. This log message indicates a normal situation, and no action is required.

TUNN_PS/6/NOTIFY_VPLS

Message

TUNN_PS/6/NOTIFY_VPLS:Notify LSP status change to VPLS.

Description

The VPLS module was notified that the LSP status changed.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

The LSP was unavailable, which was learned from the VPLS module.

Procedure

  1. If this error occurs, the system may be abnormal. Collect log information and configuration information, and then contact technical support personnel.

TUNN_PS/2/PTUNN_ID_INVALID

Message

TUNN_PS/2/PTUNN_ID_INVALID:The protection tunnel's tunnel-id is invalid!

Description

The protection tunnel ID of the protection group did not exist.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

The protection tunnel ID of the protection group did not exist.

Procedure

  1. Check whether the configuration of the protection group is correct. If incorrect, reconfigure the protection group.

TUNN_PS/1/REAL_BKP_MEM_FAIL

Message

TUNN_PS/1/REAL_BKP_MEM_FAIL:Failed to allocate the momery when processing realtime backup for PS!

Description

Failed to allocate the memory when processing realtime backup for PS.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

1. The memory block applied for was too large, and there was not enough memory to allocate.

2. The memory was used up, and no available memory existed.

Procedure

  1. Run display diagnostic-information command and save the display information. Collect log information and configuration information, and then contact technical support personnel.

TUNN_PS/5/SMOOTH_SUCCESS

Message

TUNN_PS/5/SMOOTH_SUCCESS:Tunnel PS finished smoothness successfully.

Description

The data smoothing of the protection group ended.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

After the active/standby switchover, data smoothing ended.

Procedure

  1. This log message indicates a normal situation, and no action is required.

TUNN_PS/3/SWITCH_FAIL_SMOOTH

Message

TUNN_PS/3/SWITCH_FAIL_SMOOTH:Failed to process protection switch when doing HA smooth, the work tunnel is [Index]!

Description

Failed to perform the protection switching during data smoothing.

Parameters

Parameter Name Parameter Meaning
[Index] indicates the index of a working tunnel.

Possible Causes

Failed to perform the protection switching during data smoothing.

Procedure

  1. If this error occurs, the system may be abnormal. Collect log information and configuration information, and then contact technical support personnel.

TUNN_PS/2/TUNN_ID_CFG_FAIL

Message

TUNN_PS/2/TUNN_ID_CFG_FAIL:The configured tunnel ID of protection tunnel is wrong! (ID=[ULONG])

Description

The configured ID of the protection tunnel is incorrect.

Parameters

Parameter Name Parameter Meaning
ID indicates the number of a protection tunnel.

Possible Causes

The tunnel ID is incorrect.

Procedure

  • Run the display current-configuration command to check whether the configuration is correct.

TUNN_PS/2/WTUNN_ID_INVALID

Message

TUNN_PS/2/WTUNN_ID_INVALID:The work tunnel's tunnel-id is invalid!

Description

The obtained working tunnel ID is invalid.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

The working tunnel ID is invalid.

Procedure

  1. Check whether the configuration of the protection group is correct. If incorrect, reconfigure the protection group.