S12700 V200R013C00 Log Reference

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
QinQ

QinQ

QINQ/5/ISSUSPEC_CHECK

Message

QINQ/5/ISSUSPEC_CHECK:The QinQ specifications were changed in the new version. (Spec=[STRING], Value=[ULONG])

Description

QinQ specifications were changed in the new version.

Parameters

Parameter Name Parameter Meaning
Spec Specifications
  • QINQ_ISSU_QINQ_CFG_NUM: maximum number of QinQ entries that can be configured on a sub-interface.

  • QINQ_ISSU_DOT1Q_CFG_NUM: maximum number of Dot1q entries that can be configured on a sub-interface.

  • QINQ_ISSU_STACK_CFG_NUM: maximum number of stacking entries that can be configured on a sub-interface.

  • QINQ_ISSU_VLANGROUP_MAX_NUM: maximum number of VLAN groups that can be configured on a sub-interface.

Value Value

Possible Causes

QinQ specifications were changed in the new version.

Procedure

  1. Stop the ISSU.
  2. Perform the lossy ISSU.

QINQ/5/ISSU_CHECK_ERR

Message

QINQ/5/ISSU_CHECK_ERR:The ISSU check failed because of the [STRING].

Description

The specification change or incompatibility causes the ISSU check on the QinQ module to be failed.

Parameters

Parameter Name Parameter Meaning
STRING Causes for the ISSU check failure may be:
  • failure in getting specification data: Failed to obtain the specification data.

  • specification change: Specifications were changed.

  • incompatible version: Versions were incompatible.

  • existing configuration: Other configurations existed.

Possible Causes

After checking specifications, incompatibility, and configurations, the QinQ module finds that it does not support the lossless ISSU.

Procedure

  1. Stop the ISSU.
  2. Perform the lossy ISSU.

QINQ/5/ISSU_CHECK_OK

Message

QINQ/5/ISSU_CHECK_OK:The ISSU check succeeded.

Description

The ISSU check succeeded.

Parameters

Parameter Name Parameter Meaning
None. None.

Possible Causes

After checking, the QinQ module can perform the lossless ISSU.

Procedure

  1. This log message is informational only, and no action is required.