S12700 V200R013C00 Log Reference

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
APS

APS

APS/7/DEFECT_NOTIFY_PFM

Message

APS/7/DEFECT_NOTIFY_PFM:Defect changed failed to notify plat. (EventType=[ULONG], MoudleID=[ULONG], GroupIndex=[ULONG], WorkingProtectionMiss=[ULONG], LocalSMissFarBFlag=[ULONG], ProtectionModeMiss=[ULONG], RevertiveModeMiss=[ULONG], ErrorCode=[ULONG])

Description

After detecting inconsistency, the APS state machine notified the service module of the devices to process the result. If the notification failed, the notified information was recorded for later analysis.

Parameters

Parameter Name Parameter Meaning
EventType Indicates the type of an event.
MoudleID Indicates the index of a module.
GroupIndex Indicates the index of a protection group.
WorkingProtectionMiss Indicating the working link and the protection link are inconsistent.
LocalSMissFarBFlag Indicates that the local receiving link and the remote sending link are inconsistent.
ProtectionModeMiss Indicates that the protection mode is inconsistent.
RevertiveModeMiss Indicates that the revertive mode is inconsistent.
ErrorCode Indicates an error code.

Possible Causes

After detecting inconsistency, the APS state machine failed to notify the service module of the devices to process the result.

Procedure

  1. Collect log information and configuration information, and then contact technical support personnel.

APS/7/PKT_PLAT_TO_PPI

Message

APS/7/PKT_PLAT_TO_PPI:Plat send packet templet to adapter failed.(ModuleID=[ULONG], ProtectionID=[ULONG], APSFastSndInterval=[ULONG], WtrTime=[ULONG], HoldOffTimeInterval=[ULONG], ProtectionEnable=[ULONG], APSPktFlag=[ULONG], ProtectionMode=[ULONG], ProtectionDirection=[ULONG], RevertiveMode=[ULONG], LocalState=[ULONG], GlobalState=[ULONG], APSState=[ULONG], LocalSelector=[ULONG], LocalBridge=[ULONG], SwitchCommand=[ULONG], WorkingLinkState=[ULONG], ProtectionLinkState=[ULONG], ProtectionProtocol=[ULONG], StatusSlot=[STRING], WorkingLinkManageState=[ULONG], ProtectionLinkManageState=[ULONG], ErrorCode=[ULONG])

Description

After finishing status calculation, the APS state machine sent the packet template to the device. If the sending failed, the information about the packet template was recorded for later analysis.

Parameters

Parameter Name Parameter Meaning
ModuleID Indicates the index of a module.
ProtectionID Indicates the index of a protection group.
APSFastSndInterval Indicates the interval for fast sending packets.
WtrTime Indicates the wait-to-restore time.
HoldOffTimeInterval Indicates the hold-off time.
ProtectionEnable Indicates the flag bit for enabling the protection.
APSPktFlag Indicates the flag bit for enabling packets.
ProtectionMode Indicates the protection mode.
ProtectionDirection Indicates the protection direction.
RevertiveMode Indicates the revertive mode.
LocalState Indicates the local status.
GlobalState Indicates the global status.
APSState Indicates the status of APS packets.
LocalSelector Indicates the local tunnel for selecting and receiving services.
LocalBridge Indicates the local tunnel for sending services.
SwitchCommand Indicates the local manual commands.
WorkingLinkState Indicates the status of the local working link.
ProtectionLinkState Indicates the status of the local protection link.
ProtectionProtocol Indicates the protection protocol.
StatusSlot Indicates the slot where the state machine is located.
WorkingLinkManageState Indicates the management state of the local working link.
ProtectionLinkManageState Indicates the management state of the local protection link.
ErrorCode Indicates an error code.

Possible Causes

The S12700 failed to send information about the packet template to the device.

Procedure

  1. Collect log information and configuration information, and then contact technical support personnel.

APS/7/STATE_NOTIFY_PFM

Message

APS/7/STATE_NOTIFY_PFM:State changed failed to notify plat. (EventType=[ULONG], MoudleID=[ULONG], GroupIndex=[ULONG], ProtectionType=[ULONG], LocalState=[ULONG], WorkingLinkState=[ULONG], ProtectionLinkState=[ULONG], LocalAPSRequest=[ULONG], LocalRequestedSignal=[ULONG], LocalBridgedSignal=[ULONG], FarEndRequest=[ULONG], FarABit=[ULONG], FarBBit=[ULONG], FarDBit=[ULONG], FarRBit=[ULONG], FarEndRequestedSignal=[ULONG], FarEndBridgedSignal=[ULONG], ErrorCode=[ULONG])

Description

After finishing status calculation, the APS state machine notified the service module of the devices to process the result. If the notification failed, the notified information was recorded for later analysis.

Parameters

Parameter Name Parameter Meaning
EventType Indicates the type of an event.
MoudleID Indicates the index of a module.
GroupIndex Indicates the index of a protection group.
ProtectionType Indicates the protection type.
LocalState Indicates the local status.
WorkingLinkState Indicates the status of the working link.
ProtectionLinkState Indicates the status of the protection link.
LocalAPSRequest Indicates the local APS request.
LocalRequestedSignal Indicates the flag of local receiving.
LocalBridgedSignal Indicates the flag of local sending.
FarEndRequest Indicates the request at the far end.
FarABit Indicates whether the far end uses APS packets.
FarBBit Indicates the protection mode at the far end.
FarDBit Indicates the switching mode at the far end.
FarRBit Indicates the revertive mode at the far end.
FarEndRequestedSignal Indicates the flag of receiving at the far end.
FarEndBridgedSignal Indicates the flag of sending at the far end.
ErrorCode Indicates an error code.

Possible Causes

The devices failed to notify their service module to process the result that was calculated on the APS state machine.

Procedure

  1. Collect log information and configuration information, and then contact technical support personnel.

APS/7/STATE_NOTIFY_PPI

Message

APS/7/STATE_NOTIFY_PPI:State changed failed to notify ppi. (EventType=[ULONG], MoudleID=[ULONG], ProtectionID=[ULONG], WorkingLinkIndex=[ULONG], ProntectionLinkIndex=[ULONG], HoldoffTime=[ULONG], WTRTime=[ULONG], FastSndInterval=[ULONG], ProtectionMode=[ULONG], ProtectionDirection=[ULONG], RevertiveMode=[ULONG], SwitchState=[ULONG], OldGlobalState=[ULONG], SwitchResult=[ULONG], ProtectionEnableFlag=[ULONG], SwitchCommand=[ULONG], WorkingLinkState=[ULONG], ProtectionLinkState=[ULONG], ErrorCode=[ULONG])

Description

After finishing status calculation, the APS state machine notified the device to process the result. If the notification failed, the notified information was recorded for later analysis.

Parameters

Parameter Name Parameter Meaning
EventType Indicates the type of an event.
MoudleID Indicates the index of a module.
GroupIndex Indicates the index of a protection group.
ProtectionType Indicates the index of the working link.
LocalState Indicates the index of the protection link.
WorkingLinkState Indicates the hold-off time.
ProtectionLinkState Indicates the wait-to-restore time.
LocalAPSRequest Indicates the interval for fast sending packets.
LocalRequestedSignal Indicates the protection mode.
LocalBridgedSignal Indicates the protection direction.
FarEndRequest Indicates the revertive mode.
FarABit Indicates the switching status.
FarBBit Indicates the original priority status.
FarDBit Indicates the switching result.
FarRBit Indicates the flag for enabling the protection.
FarEndRequestedSignal Indicates the command for switching.
FarEndBridgedSignal Indicates the status of the working link.
ErrorCode Indicates an error code.

Possible Causes

The S12700 failed to notify the device to process the result that was calculated on the APS state machine.

Procedure

  1. Collect log information and configuration information, and then contact technical support personnel.

APS/7/SYN_MES_IO_TO_MAIN

Message

APS/7/SYN_MES_IO_TO_MAIN:IO board synchronization message to main board failed. (Mid=[ULONG], GroupIndex=[ULONG], SwitchRequest=[ULONG], DefectDirection=[ULONG], StatusSlot=[STRING], SourceSlot=[STRING], ErrorCode=[ULONG])

Description

The APS module on the interface board failed to send information to the main control board.

Parameters

Parameter Name Parameter Meaning
Mid Indicates the index of a module.
GroupIndex Indicates the index of a protection group.
SwitchRequest Indicates the request for switching.
DefectDirection Indicates the switching direction.
StatusSlot Indicates the slot where the state machine is located.
SourceSlot Indicates the slot where the information comes from.
ErrorCode Indicates an error code.

Possible Causes

The APS module on the interface board failed to send information to the main control board.

Procedure

  1. Collect log information and configuration information, and then contact technical support personnel.

APS/7/SYN_MES_MAIN_TO_IO

Message

APS/7/SYN_MES_MAIN_TO_IO:Main board synchronization message to IO board failed. (Mid=[ULONG], GroupIndex=[ULONG], SwitchRequest=[ULONG], DefectDirection=[ULONG], StatusSlot=[STRING], SourceSlot=[STRING], ErrorCode=[ULONG])

Description

The APS module on the main control board failed to send information to the interface board.

Parameters

Parameter Name Parameter Meaning
Mid Indicates the index of a module.
GroupIndex Indicates the index of a protection group.
SwitchRequest Indicates the request for switching.
DefectDirection Indicates the switching direction.
StatusSlot Indicates the slot where the state machine is located.
SourceSlot Indicates the slot where the information comes from.
ErrorCode Indicates an error code.

Possible Causes

The APS module on the main control board failed to send information to the interface board.

Procedure

  1. Collect log information and configuration information, and then contact technical support personnel.